Accessories availableYesActuator markingI / OActuator materialInsulation Group II, Black, SealableContact position indicationRed ON / Green OFFDielectric test voltage50/60 Hz, 1 min- 2 kVElectrical endurance20000 AC cycleFrequency50 HzHousing materialInsulation Group II, RAL 7035Input voltage typeAC/DCInstallation sizeacc. to DIN 43880 1Mechanical endurance20000 cycleMounting positionanyNumber of protected poles3Operational voltageMaximum (Incl. Tolerance) 440 V ACOvervoltage categoryIIIPower supply connectionArbitraryProduct rangeS200Rated conditional short-circuit current(230 V) 20 kA(400 V) 20 kARated current (In)2 ARated impulse withstand voltage4 kVat 2000 m 5 kVat Sea Level 6.2 kVRated insulation voltageacc. to IEC/EN 60664-1 440 VRated operational voltageacc. to IEC 60898-1 400 V ACacc. to IEC 60947-2 440 V ACRated service short-circuit breaking capacity(230 V AC) 15 kA(400 V AC) 7.5 kA(440 V AC) 7.5 kARated short-circuit capacity(AC) 6 kA(DC) 6 kA(400 V AC) 6 kARated ultimate short-circuit breaking capacity(230 V AC) 20 kA(400 V AC) 10 kA(440 V AC) 10 kARecommended screw driverPozidriv 2Screw terminal typeFailsafe Bi-directional Cylinder-lift TerminalTightening torque2.8 NmTripping characteristicKWire stripping length12.5 mm

Specifications

Accessories availableYes
Actuator markingI / O
Actuator materialInsulation Group II, Black, Sealable
Contact position indicationRed ON / Green OFF
Dielectric test voltage50/60 Hz, 1 min- 2 kV
Electrical endurance20000 AC cycle
Frequency50 Hz
Housing materialInsulation Group II, RAL 7035
Input voltage typeAC/DC
Installation sizeacc. to DIN 43880 1
Mechanical endurance20000 cycle
Mounting positionany
Number of protected poles3
Operational voltageMaximum (Incl. Tolerance) 440 V AC
Overvoltage categoryIII
Power supply connectionArbitrary
Product rangeS200
Rated conditional short-circuit current(230 V) 20 kA(400 V) 20 kA
Rated current (In)2 A
Rated impulse withstand voltage4 kVat 2000 m 5 kVat Sea Level 6.2 kV
Rated insulation voltageacc. to IEC/EN 60664-1 440 V
Rated operational voltageacc. to IEC 60898-1 400 V ACacc. to IEC 60947-2 440 V AC
Rated service short-circuit breaking capacity(230 V AC) 15 kA(400 V AC) 7.5 kA(440 V AC) 7.5 kA
Rated short-circuit capacity(AC) 6 kA(DC) 6 kA(400 V AC) 6 kA
Rated ultimate short-circuit breaking capacity(230 V AC) 20 kA(400 V AC) 10 kA(440 V AC) 10 kA
Recommended screw driverPozidriv 2
Screw terminal typeFailsafe Bi-directional Cylinder-lift Terminal
Tightening torque2.8 Nm
Tripping characteristicK
Wire stripping length12.5 mm