HPS DM145JCC DIT 145kVA 460-230 CU Drive Isolation Transformers

$8,902.44
Quantity
Add to wishlist
Usually in stock

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

Guarantee safe & secure checkout

ApprovalCSA, ULDrive isolation transformer3ph 145kVA 460V-230Y/133V 60Hz CUDutyGeneral dutyEfficiency regulationNot specified (USA)Enclosure dimensions41in/1042mm(H), 32in/813mm(W), 25.5in/648mm(D)Enclosure finishANSI 61 grey, UL50Enclosure IR windowNoEnclosure PN (NPL)NH4-N3REnclosure typeType 3R / IP24Frequency60HzImpedance (std)3% - 6%Insulation class220°CMaterialCopperMotor HPNot SelectedNameplateHPS standardNet weight (NPL)955 lb / 434 kgNumber of secondaries1 (6-pulse)PhaseThree phasePrimary connectionDeltaPrimary FCAN (NPL)1x5%Primary FCBN (NPL)1x5%Primary termination (NPL)Mechanical lugsPrimary voltage460DRating145 kVASecondary connectionWye-NSecondary termination (NPL)Mounting padsSecondary voltage230Y/133Seismic complianceIBC 2018 (Sds=2.0, z/h=0, lp=1.5)Sound level50 dBA (NEMA ST-20)Standard kVA145Temperature rise150°CThermal protective deviceNormally closed (all coils) thermostats with 200°C setpoint, typically built to orderVector configurationDyn1 (-30°)

Specifications

ApprovalCSA, UL
Drive isolation transformer3ph 145kVA 460V-230Y/133V 60Hz CU
DutyGeneral duty
Efficiency regulationNot specified (USA)
Enclosure dimensions41in/1042mm(H), 32in/813mm(W), 25.5in/648mm(D)
Enclosure finishANSI 61 grey, UL50
Enclosure IR windowNo
Enclosure PN (NPL)NH4-N3R
Enclosure typeType 3R / IP24
Frequency60Hz
Impedance (std)3% - 6%
Insulation class220°C
MaterialCopper
Motor HPNot Selected
NameplateHPS standard
Net weight (NPL)955 lb / 434 kg
Number of secondaries1 (6-pulse)
PhaseThree phase
Primary connectionDelta
Primary FCAN (NPL)1x5%
Primary FCBN (NPL)1x5%
Primary termination (NPL)Mechanical lugs
Primary voltage460D
Rating145 kVA
Secondary connectionWye-N
Secondary termination (NPL)Mounting pads
Secondary voltage230Y/133
Seismic complianceIBC 2018 (Sds=2.0, z/h=0, lp=1.5)
Sound level50 dBA (NEMA ST-20)
Standard kVA145
Temperature rise150°C
Thermal protective deviceNormally closed (all coils) thermostats with 200°C setpoint, typically built to order
Vector configurationDyn1 (-30°)

DM145JCC