Meltric 63-38042-972 DSN30 INLET POLY BLUE SIZE 2 TYPE 4X IP 69 2P+G 30 A 480 VAC 60 Hz +2 AUX

$117.86
Quantity
Add to wishlist
Usually in stock

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

Guarantee safe & secure checkout

Accessory Size2Aux Condenser Strip Length3/4 IN OR 19 MMAux Contact Max Voltage Rating600VACAux Pilot Contact Current Rating1.2AAux Term Tightening Torque15 IN-LBS / 1.7 N-MAux Term TypeSCREWAux Term Wire Cap Max14 AWGAux Term Wire Cap Min14 AWGBranch Switch RatingBRANCH CIRCUIT DISCONNECT SWITCHCSA List File155873CSA List Std 1C22.2 No. 182.1-13CSA ListingcCSAusCurrent Interrupting RatingSWITCH RATEDFrequency60 HzHP5Impact RatingIK09Keying Position4Load Break Abnormal Overload45 ALoad Break Normal Operation30 AMaterialPOLYMaximum Operating Temperature-C60CMaximum Operating Temperature-F140FMinimum Operating Temperature-C-40CMinimum Operating Temperature-F-40FMotor Switch RatingMOTOR CIRCUIT DISCONNECT SWITCHNEMA Watertightness4XNumber Of Auxiliary Contacts+2 AUXNumber of Notch Pos24Phase Condenser Strip Length3/4 IN OR 19 MMPhase Term Tightening Torque15 IN-LBS / 1.7 N-MPhase Term TypeSCREW TERMINALPhase Term Wire Cap Max THHN8 AWGPhase Term Wire Cap Max Type W8 AWGPhase Term Wire Cap Min THHN14 AWGPhase Term Wire Cap Min Type W14 AWGPrimary IP Rating66/67Prod Wire Temperature Rating60CProduct ColorBLUERated Current30 ARated Voltage480 VACSecondary IP Rating69Short Circuit Rating100 kA - CLOSE & WITHSTANDShort Circuit Rating Fusing100 kA 125 A (400%) RK1 NTDUl List FileE79796 VOLUME 8 SECTION 1Ul List Std 1UL 1682Ul List Std 2UL 2682Ul ListingULCUl508 Pilot Rating2 @ code A600Voltage Color CodeRED

Specifications

Accessory Size2
Aux Condenser Strip Length3/4 IN OR 19 MM
Aux Contact Max Voltage Rating600VAC
Aux Pilot Contact Current Rating1.2A
Aux Term Tightening Torque15 IN-LBS / 1.7 N-M
Aux Term TypeSCREW
Aux Term Wire Cap Max14 AWG
Aux Term Wire Cap Min14 AWG
Branch Switch RatingBRANCH CIRCUIT DISCONNECT SWITCH
CSA List File155873
CSA List Std 1C22.2 No. 182.1-13
CSA ListingcCSAus
Current Interrupting RatingSWITCH RATED
Frequency60 Hz
HP5
Impact RatingIK09
Keying Position4
Load Break Abnormal Overload45 A
Load Break Normal Operation30 A
MaterialPOLY
Maximum Operating Temperature-C60C
Maximum Operating Temperature-F140F
Minimum Operating Temperature-C-40C
Minimum Operating Temperature-F-40F
Motor Switch RatingMOTOR CIRCUIT DISCONNECT SWITCH
NEMA Watertightness4X
Number Of Auxiliary Contacts+2 AUX
Number of Notch Pos24
Phase Condenser Strip Length3/4 IN OR 19 MM
Phase Term Tightening Torque15 IN-LBS / 1.7 N-M
Phase Term TypeSCREW TERMINAL
Phase Term Wire Cap Max THHN8 AWG
Phase Term Wire Cap Max Type W8 AWG
Phase Term Wire Cap Min THHN14 AWG
Phase Term Wire Cap Min Type W14 AWG
Primary IP Rating66/67
Prod Wire Temperature Rating60C
Product ColorBLUE
Rated Current30 A
Rated Voltage480 VAC
Secondary IP Rating69
Short Circuit Rating100 kA - CLOSE & WITHSTAND
Short Circuit Rating Fusing100 kA 125 A (400%) RK1 NTD
Ul List FileE79796 VOLUME 8 SECTION 1
Ul List Std 1UL 1682
Ul List Std 2UL 2682
Ul ListingULC
Ul508 Pilot Rating2 @ code A600
Voltage Color CodeRED