Action type of the contact element (acc. to IEC 60947-5-1)Snap action contactsActuation speedacc. to IEC 60947-5-1 Max. 1.5 m/sacc. to IEC 60947-5-1 Min. 0 m/sActuation torqueacc. to IEC 60947-5-1 Min. 0.15 N·mAngular head adjustmentadjustable head every 90°Angular lever adjustment9° in 9°B10d value50 Millions operationsClimatic withstandaccording to IEC 68-2-3 and salty mist according to IEC 68-2-11Connecting capacityBar AWG 20 ... AWG 14 mm²Bar 0.5 ... 2.5 mm²Connecting terminalsM3.5 (+,-) pozidriv 2 screw with cable clampConsistency (measured over 1 million operations)0.05 mmContact element form (acc. to IEC 60947-5-1)ZbConventional free-air thermal currentacc. to IEC 60947-5-1, q = 40 °C 10 ADegree of protectionacc. to IEC 60529 IP66Electrical shock protection acc. to IEC 536Class IMaximum electrical switching frequency3600 cycles per hour(AC-15) 3600 cycles per hour(DC-13) 3600 cycles per hourMechanical durability0 cycleMounting by screws2 or 4 x M5 screwsMovement to be detected30° Cam Translation MovementNumber and type of bottom cable glands1/2 NPT cable glandNumber of auxiliary contacts NC1Number of auxiliary contacts NO1Pilot duty UL/CSAA600Q600Positive opening operation of NC contactsNoRated impulse withstand voltage6 kVRated insulation voltageacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 Vacc. to UL/CSA 600 VRated operational current AC-15(230 V AC) 3.1 A(400 V) NC 4(24 V) 10 A(130 V) 5.5 A(240 V) 3 ARated operational current DC-13(24 V) 6 A(110 V) 0.6 A(125 V) 0.55 A(250 V) 0.4 AResistance between contacts2.50E+46Short-circuit protective devicesgG Type Fuses 10 ATerminal for protective conductorM 3.5 (+,-) pozidriv 2 screw with cable clampTerminal markingaccording to EN 50013

Specifications

Action type of the contact element (acc. to IEC 60947-5-1)Snap action contacts
Actuation speedacc. to IEC 60947-5-1 Max. 1.5 m/sacc. to IEC 60947-5-1 Min. 0 m/s
Actuation torqueacc. to IEC 60947-5-1 Min. 0.15 N·m
Angular head adjustmentadjustable head every 90°
Angular lever adjustment9° in 9°
B10d value50 Millions operations
Climatic withstandaccording to IEC 68-2-3 and salty mist according to IEC 68-2-11
Connecting capacityBar AWG 20 ... AWG 14 mm²Bar 0.5 ... 2.5 mm²
Connecting terminalsM3.5 (+,-) pozidriv 2 screw with cable clamp
Consistency (measured over 1 million operations)0.05 mm
Contact element form (acc. to IEC 60947-5-1)Zb
Conventional free-air thermal currentacc. to IEC 60947-5-1, q = 40 °C 10 A
Degree of protectionacc. to IEC 60529 IP66
Electrical shock protection acc. to IEC 536Class I
Maximum electrical switching frequency3600 cycles per hour(AC-15) 3600 cycles per hour(DC-13) 3600 cycles per hour
Mechanical durability0 cycle
Mounting by screws2 or 4 x M5 screws
Movement to be detected30° Cam Translation Movement
Number and type of bottom cable glands1/2 NPT cable gland
Number of auxiliary contacts NC1
Number of auxiliary contacts NO1
Pilot duty UL/CSAA600Q600
Positive opening operation of NC contactsNo
Rated impulse withstand voltage6 kV
Rated insulation voltageacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 Vacc. to UL/CSA 600 V
Rated operational current AC-15(230 V AC) 3.1 A(400 V) NC 4(24 V) 10 A(130 V) 5.5 A(240 V) 3 A
Rated operational current DC-13(24 V) 6 A(110 V) 0.6 A(125 V) 0.55 A(250 V) 0.4 A
Resistance between contacts2.50E+46
Short-circuit protective devicesgG Type Fuses 10 A
Terminal for protective conductorM 3.5 (+,-) pozidriv 2 screw with cable clamp
Terminal markingaccording to EN 50013