440 V DC440 V DCActuator typeRotary HandleAmbient air temperature compensationYesAmpere rating UL/CSA20 AATEX certificate1SAA918000-3903BV certificate1SAA918000-0204CB certificate1SAA918000-2002CCC certificate1SAA918000-3806Connecting capacity main circuit UL/CSAFlexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWGContact position indicationON / OFFConventional free-air thermal current (Ith)Main Circuit 20 ACountry of OriginCzech Republic (CZ)cUL certificatecUL_E137861 cUL_E345003Current20 AData sheet, technical information2CDC131046D0201Data sheet, technical information (Part 2)1SAM100513F0013Declaration of conformity - CE1SAD938513-0003Degree of protectionIP20DNV certificate1SAA918000-0305eClass7.0 27370401Electrical durability50000 cycleETIM 4EC000074 - Motor protective circuit-breakerETIM 5EC000074 - Motor protective circuit-breakerETIM 6EC000074 - Motor protection circuit-breakerGL certificate1SAA918000-0403GOST certificate1SAA918000-2703Lead time14 day(s)LR certificate1SAA918000-0503Made to orderNoMax operating altitude permissible2000 mMaximum operating voltage UL/CSAMain Circuit 600 V ACMechanical durability100000 cycleMounting positionPosition 1 to 6Number of poles3Object classification codeFPoles3Pollution degree3Power lossat Rated Operating Conditions per Pole 1.0 ... 1.6 WProduct sales statusInactiveQuote onlyNoRated frequencyMain Circuit 50 Hz Main Circuit 60 HzRated impulse withstand voltage (U imp)Main Circuit 6 kVRated instantaneous short-circuit current setting (Ii)300 ARated insulation voltage (Ui)690 VRated operational current (Ie)20 ARated operational current AC-3 (Ie)20 ARated operational power AC-3 (Pe)(400 V) Three Phase 7.5 kWRated operational voltageMain Circuit 690 V AC Main Circuit 440 V DCRated service short-circuit breaking capacity (Ics)(230 V AC) 100 kA (400 V AC) 55 kA (440 V AC) 35 kA (500 V AC) 22 kA (690 V AC) 3.5 kARated ultimate short-circuit breaking capacity (Icu)(230 V AC) 100 kA (400 V AC) 55 kA (440 V AC) 35 kA (500 V AC) 22 kA (690

Specifications

440 V DC440 V DC
Actuator typeRotary Handle
Ambient air temperature compensationYes
Ampere rating UL/CSA20 A
ATEX certificate1SAA918000-3903
BV certificate1SAA918000-0204
CB certificate1SAA918000-2002
CCC certificate1SAA918000-3806
Connecting capacity main circuit UL/CSAFlexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWG
Contact position indicationON / OFF
Conventional free-air thermal current (Ith)Main Circuit 20 A
Country of OriginCzech Republic (CZ)
cUL certificatecUL_E137861 cUL_E345003
Current20 A
Data sheet, technical information2CDC131046D0201
Data sheet, technical information (Part 2)1SAM100513F0013
Declaration of conformity - CE1SAD938513-0003
Degree of protectionIP20
DNV certificate1SAA918000-0305
eClass7.0 27370401
Electrical durability50000 cycle
ETIM 4EC000074 - Motor protective circuit-breaker
ETIM 5EC000074 - Motor protective circuit-breaker
ETIM 6EC000074 - Motor protection circuit-breaker
GL certificate1SAA918000-0403
GOST certificate1SAA918000-2703
Lead time14 day(s)
LR certificate1SAA918000-0503
Made to orderNo
Max operating altitude permissible2000 m
Maximum operating voltage UL/CSAMain Circuit 600 V AC
Mechanical durability100000 cycle
Mounting positionPosition 1 to 6
Number of poles3
Object classification codeF
Poles3
Pollution degree3
Power lossat Rated Operating Conditions per Pole 1.0 ... 1.6 W
Product sales statusInactive
Quote onlyNo
Rated frequencyMain Circuit 50 Hz Main Circuit 60 Hz
Rated impulse withstand voltage (U imp)Main Circuit 6 kV
Rated instantaneous short-circuit current setting (Ii)300 A
Rated insulation voltage (Ui)690 V
Rated operational current (Ie)20 A
Rated operational current AC-3 (Ie)20 A
Rated operational power AC-3 (Pe)(400 V) Three Phase 7.5 kW
Rated operational voltageMain Circuit 690 V AC Main Circuit 440 V DC
Rated service short-circuit breaking capacity (Ics)(230 V AC) 100 kA (400 V AC) 55 kA (440 V AC) 35 kA (500 V AC) 22 kA (690 V AC) 3.5 kA
Rated ultimate short-circuit breaking capacity (Icu)(230 V AC) 100 kA (400 V AC) 55 kA (440 V AC) 35 kA (500 V AC) 22 kA (690 V AC) 3.5 kA
Recommended screw driverM3.5 Pozidriv 2
Resistance to shock acc. to IEC 60068-2-2711 ms Pulse 15g
Resistance to vibrations acc. to IEC 60068-2-65g / 10 ... 150 Hz
RINA certificate1SAA918000-0803
RMRS certificate1SAA918000-0703
RoHS information1SAA918001-4401
RoHS statusFollowing EU Directive 2002/95/EC August 18, 2005 and amendment
Setting range16 ... 20 A
StandardsIEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1
Tightening torqueMain Circuit 1.4 Nm
Tightening torque UL/CSAAuxiliary Circuit 7 inlb Main Circuit 14 inlb
UL certificateUL_E137861 UL_E345003
Voltage690 V AC
Wire stripping lengthAuxiliary Circuit 8 mm Main Circuit 10 mm