ABS certificate1SAA963000-0104Actuator typeRotary HandleAmbient air temperature compensationYesAmpere rating UL/CSA0.16 ABV certificate1SAA963000-0202CB certificate1SAA963000-2003CCC certificate1SAA963000-3803Connecting capacity main circuit UL/CSAFlexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWGContact position indicationON / OFFConventional free-air thermal current (Ith)Main Circuit 0.16 AcUL certificatecUL_E137861Data sheet, technical information2CDC131025D0201Data sheet, technical information (Part 2)1SAM200505F0001Data sheet, technical information (Part 3)1SAM200507F0001 1SAM200507F0002 1SAM200507F0003 1SAM200508F0001 1SAM200508F0002 1SAM200508F0003Declaration of conformity - CE1SAD938516-0060Degree of protectionHousing IP20 Main Circuit Terminals IP10DNV certificate1SAA963000-0303E-nummer3111930EAC certificate1SAA963000-2701eClass7.0 27370401Electrical durability100000 cycleETIM 4EC000074 - Motor protective circuit-breakerETIM 5EC000074 - Motor protective circuit-breakerETIM 6EC000074 - Motor protection circuit-breakerGeneral use rating UL/CSA(600 V AC) 0.16 AGL certificate1SAA963000-0402GOST certificate1SAA963001-2702LR certificate1SAA963000-0505Max operating altitude permissible2000 mMaximum operating voltage UL/CSAMain Circuit 600 V ACMechanical durability100000 cycleMounting positionPosition 1 to 6Number of poles3Object classification codeFPollution degree3Power lossat Rated Operating Conditions per Pole 0.7 ... 1.7 WRated frequencyMain Circuit 50 Hz Main Circuit 60 HzRated impulse withstand voltage (U imp)Main Circuit 6 kVRated instantaneous short-circuit current setting (Ii)2 ARated insulation voltage (Ui)690 VRated operational current (Ie)0.16 ARated operational current AC-3 (Ie)0.16 ARated operational power AC-3 (Pe)(400 V) Three Phase 0.03 kWRated operational voltageMain Circuit 690 V ACRated service short-circuit breaking capacity (Ics)(230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 30 kA (500 V AC) 30 kA (690 V AC) 30 kARated ultimate short-circuit break

Specifications

ABS certificate1SAA963000-0104
Actuator typeRotary Handle
Ambient air temperature compensationYes
Ampere rating UL/CSA0.16 A
BV certificate1SAA963000-0202
CB certificate1SAA963000-2003
CCC certificate1SAA963000-3803
Connecting capacity main circuit UL/CSAFlexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWG
Contact position indicationON / OFF
Conventional free-air thermal current (Ith)Main Circuit 0.16 A
cUL certificatecUL_E137861
Data sheet, technical information2CDC131025D0201
Data sheet, technical information (Part 2)1SAM200505F0001
Data sheet, technical information (Part 3)1SAM200507F0001 1SAM200507F0002 1SAM200507F0003 1SAM200508F0001 1SAM200508F0002 1SAM200508F0003
Declaration of conformity - CE1SAD938516-0060
Degree of protectionHousing IP20 Main Circuit Terminals IP10
DNV certificate1SAA963000-0303
E-nummer3111930
EAC certificate1SAA963000-2701
eClass7.0 27370401
Electrical durability100000 cycle
ETIM 4EC000074 - Motor protective circuit-breaker
ETIM 5EC000074 - Motor protective circuit-breaker
ETIM 6EC000074 - Motor protection circuit-breaker
General use rating UL/CSA(600 V AC) 0.16 A
GL certificate1SAA963000-0402
GOST certificate1SAA963001-2702
LR certificate1SAA963000-0505
Max operating altitude permissible2000 m
Maximum operating voltage UL/CSAMain Circuit 600 V AC
Mechanical durability100000 cycle
Mounting positionPosition 1 to 6
Number of poles3
Object classification codeF
Pollution degree3
Power lossat Rated Operating Conditions per Pole 0.7 ... 1.7 W
Rated frequencyMain Circuit 50 Hz Main Circuit 60 Hz
Rated impulse withstand voltage (U imp)Main Circuit 6 kV
Rated instantaneous short-circuit current setting (Ii)2 A
Rated insulation voltage (Ui)690 V
Rated operational current (Ie)0.16 A
Rated operational current AC-3 (Ie)0.16 A
Rated operational power AC-3 (Pe)(400 V) Three Phase 0.03 kW
Rated operational voltageMain Circuit 690 V AC
Rated service short-circuit breaking capacity (Ics)(230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 30 kA (500 V AC) 30 kA (690 V AC) 30 kA
Rated ultimate short-circuit breaking capacity (Icu)(230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 30 kA (500 V AC) 30 kA (690 V AC) 30 kA
Recommended screw driverPozidriv 2
Resistance to shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz
RMRS certificate1SAA918000-0703
RoHS information1SAA963001-4407
RoHS statusFollowing EU Directive 2002/95/EC August 18, 2005 and amendment
Setting range0.1 ... 0.16 A
StandardsIEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1
Tightening torqueMain Circuit 0.8 ... 1.2 Nm
Tightening torque UL/CSAMain Circuit 10 inlb
UL certificateUL_E137861
Wire stripping lengthMain Circuit 9 mm