ASEFA certificateASEFA_05203BTCB certificateCB_FR_617239ACCC certificateCCC_2004010304112227Climatic withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification IICoil consumptionAverage Holding Value, from Warm State 3 W Average Pull-in Value, from Cold State 3 WCoil operating limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) CConnecting capacity auxiliary circuitFlexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mmConnecting capacity main circuitFlexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mmConnecting terminals (delivered in open position) main polesM 3.5 (+,-) pozidriv 2 screw with cable clampConventional free-air thermal current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 C 30 A acc. to IEC 60947-5-1, q = 40 C 16 ACSA certificateCSA_1041746cUL certificateUL_20160205-E312527-10-2Data sheet, technical information1SBC100122C0202_Ch02Declaration of conformity - CE1SBD250804U1000Degree of protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20ETIM 4EC000066 - Magnet contactor, AC-switchingETIM 5EC000066 - Magnet contactor, AC-switchingETIM 6EC000066 - Power contactor, AC switchingGL certificateGL_26144_05HHGOST certificateGOST_POCCFRME77B07175LOVAG certificateLOVAG_FR03023-FR03029Max electrical switching frequencyAC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hourMax mechanical switching frequency3600 cycles per hourMax operating altitude permissible3000 mMechanical durability10 millionNumber of auxiliary contacts NC0Number of auxiliary contacts NO1Number of main contacts NC0Number of main contacts NO3Object classification codeQRated breaking capacity AC-3 acc. to IEC 60947-4-18 x Ie AC-3Rated control circuit voltage (Uc)DC Operation 12 VRated frequencySupply Circuit 50 Hz Supply Circuit 60 HzRated impulse withstand voltage (U imp)8 kVRated insulation voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 VRated making capacity AC-3 acc. to
| ASEFA certificate | ASEFA_05203BT |
| CB certificate | CB_FR_617239A |
| CCC certificate | CCC_2004010304112227 |
| Climatic withstand | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
| Coil consumption | Average Holding Value, from Warm State 3 W Average Pull-in Value, from Cold State 3 W |
| Coil operating limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C |
| Connecting capacity auxiliary circuit | Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm |
| Connecting capacity main circuit | Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm |
| Connecting terminals (delivered in open position) main poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Conventional free-air thermal current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 C 30 A acc. to IEC 60947-5-1, q = 40 C 16 A |
| CSA certificate | CSA_1041746 |
| cUL certificate | UL_20160205-E312527-10-2 |
| Data sheet, technical information | 1SBC100122C0202_Ch02 |
| Declaration of conformity - CE | 1SBD250804U1000 |
| Degree of protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| ETIM 4 | EC000066 - Magnet contactor, AC-switching |
| ETIM 5 | EC000066 - Magnet contactor, AC-switching |
| ETIM 6 | EC000066 - Power contactor, AC switching |
| GL certificate | GL_26144_05HH |
| GOST certificate | GOST_POCCFRME77B07175 |
| LOVAG certificate | LOVAG_FR03023-FR03029 |
| Max electrical switching frequency | AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour |
| Max mechanical switching frequency | 3600 cycles per hour |
| Max operating altitude permissible | 3000 m |
| Mechanical durability | 10 million |
| Number of auxiliary contacts NC | 0 |
| Number of auxiliary contacts NO | 1 |
| Number of main contacts NC | 0 |
| Number of main contacts NO | 3 |
| Object classification code | Q |
| Rated breaking capacity AC-3 acc. to IEC 60947-4-1 | 8 x Ie AC-3 |
| Rated control circuit voltage (Uc) | DC Operation 12 V |
| Rated frequency | Supply Circuit 50 Hz Supply Circuit 60 Hz |
| Rated impulse withstand voltage (U imp) | 8 kV |
| Rated insulation voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V |
| Rated making capacity AC-3 acc. to IEC 60947-4-1 | 10 x Ie AC-3 |
| Rated operational current AC-1 (Ie) | (690 V) 40 C 30 A (690 V) 55 C 27 A (690 V) 70 C 23 A |
| Rated operational current AC-15 (Ie) | (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A |
| Rated operational current DC-13 (Ie) | (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A |
| Rated operational power AC-3 (Pe) | (220 / 230 / 240 V) 4 kW (380 / 400 V) 7.5 kW (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW |
| Rated operational voltage | Auxiliary Circuit 690 V Main Circuit 690 V |
| RoHS information | 1SBD350051R1000 |
| RoHS status | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| Short-circuit protective devices | Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 32 A |
| Terminal type | Screw terminals |
| UL listing card | UL_E312527 |