Cart
Custom content
<p>This is custom content</p>

HPS DM014KDCN DRIVE 3PH 14kVA 480-240 CU Drive Isolation Transformers

$2,708.54
Quantity
Add to wishlist
Usually in stock

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

Guarantee safe & secure checkout

ApprovalCSA, ULDrive isolation transformer3ph 14kVA 480V-240Y/139V 60Hz CUDutyGeneral dutyEfficiency regulationNot specified (USA)Enclosure dimensions21.5in/547mm(H), 19.38in/493mm(W), 20.2in/514mm(D)Enclosure finishANSI 61 grey, UL50Enclosure IR windowNoEnclosure PN (NPL)NH5-N3REnclosure typeType 3R / IP24Frequency60HzImpedance (std)3% - 6%Insulation class200°CMaterialCopperMotor HPNot SelectedNameplateHPS standardNet weight (NPL)185 lb / 84 kgNumber of secondaries1 (6-pulse)PhaseThree phasePrimary connectionDeltaPrimary FCAN (NPL)1x5%Primary FCBN (NPL)1x5%Primary termination (NPL)Terminal blockPrimary voltage480DRating14 kVASecondary connectionWye-NSecondary termination (NPL)Terminal blockSecondary voltage240Y/139Seismic complianceIBC 2018 (Sds=2.0, z/h=0, lp=1.5)Sound level45 dBA (NEMA ST-20)Standard kVA14Temperature rise130°CThermal protective deviceNormally closed (all coils) thermostats with 185°C setpoint, typically built to orderVector configurationDyn1 (-30°)

Specifications

ApprovalCSA, UL
Drive isolation transformer3ph 14kVA 480V-240Y/139V 60Hz CU
DutyGeneral duty
Efficiency regulationNot specified (USA)
Enclosure dimensions21.5in/547mm(H), 19.38in/493mm(W), 20.2in/514mm(D)
Enclosure finishANSI 61 grey, UL50
Enclosure IR windowNo
Enclosure PN (NPL)NH5-N3R
Enclosure typeType 3R / IP24
Frequency60Hz
Impedance (std)3% - 6%
Insulation class200°C
MaterialCopper
Motor HPNot Selected
NameplateHPS standard
Net weight (NPL)185 lb / 84 kg
Number of secondaries1 (6-pulse)
PhaseThree phase
Primary connectionDelta
Primary FCAN (NPL)1x5%
Primary FCBN (NPL)1x5%
Primary termination (NPL)Terminal block
Primary voltage480D
Rating14 kVA
Secondary connectionWye-N
Secondary termination (NPL)Terminal block
Secondary voltage240Y/139
Seismic complianceIBC 2018 (Sds=2.0, z/h=0, lp=1.5)
Sound level45 dBA (NEMA ST-20)
Standard kVA14
Temperature rise130°C
Thermal protective deviceNormally closed (all coils) thermostats with 185°C setpoint, typically built to order
Vector configurationDyn1 (-30°)

DM014KDCN

16 other products in the same category:

This website uses cookies to ensure you get the best experience on our website