Guarantee safe & secure checkout

Accessories availableYesActuator markingI / OActuator materialInsulation Group II, Black, SealableContact position indicationRed ON / Green OFFEnergy limiting class3Housing materialInsulation Group II, RAL 7035Input voltage typeACInstallation sizeacc. to DIN 43880 1Mechanical endurance20000 cycleMounting positionanyNumber of protected poles3Overvoltage categoryIIIPower supply connectionArbitraryProduct rangeS200PRated conditional short-circuit current(230 V) 25 kA(400 V) 25 kARated current (In)3 ARated impulse withstand voltage4 kVat 2000 m 5 kVat Sea Level 6.2 kVRated insulation voltageacc. to IEC/EN 60664-1 440 VRated operational voltageacc. to IEC 60898-1 400 V ACacc. to IEC 60947-2 400 V ACRated service short-circuit breaking capacity(400 V AC) 12.5 kARated short-circuit capacity(230 V AC) 12.5 kA(400 V AC) 12.5 kARated ultimate short-circuit breaking capacity(230 V AC) 25 kA(400 V AC) 25 kARecommended screw driverPozidriv 2Screw terminal typeFailsafe Bi-directional Cylinder-lift TerminalTightening torque2.8 NmTripping characteristicK

Specifications

Accessories availableYes
Actuator markingI / O
Actuator materialInsulation Group II, Black, Sealable
Contact position indicationRed ON / Green OFF
Energy limiting class3
Housing materialInsulation Group II, RAL 7035
Input voltage typeAC
Installation sizeacc. to DIN 43880 1
Mechanical endurance20000 cycle
Mounting positionany
Number of protected poles3
Overvoltage categoryIII
Power supply connectionArbitrary
Product rangeS200P
Rated conditional short-circuit current(230 V) 25 kA(400 V) 25 kA
Rated current (In)3 A
Rated impulse withstand voltage4 kVat 2000 m 5 kVat Sea Level 6.2 kV
Rated insulation voltageacc. to IEC/EN 60664-1 440 V
Rated operational voltageacc. to IEC 60898-1 400 V ACacc. to IEC 60947-2 400 V AC
Rated service short-circuit breaking capacity(400 V AC) 12.5 kA
Rated short-circuit capacity(230 V AC) 12.5 kA(400 V AC) 12.5 kA
Rated ultimate short-circuit breaking capacity(230 V AC) 25 kA(400 V AC) 25 kA
Recommended screw driverPozidriv 2
Screw terminal typeFailsafe Bi-directional Cylinder-lift Terminal
Tightening torque2.8 Nm
Tripping characteristicK