Meltric 33-38042-974 DS30 INLET POLY BLUE SIZE 3 TYPE 3R 2P+G 30 A 480 VAC 60 Hz +4 AUX

$189.33
Quantity
Add to wishlist
Usually in stock

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

Guarantee safe & secure checkout

Accessory Size3Aux Contact Max Voltage Rating600VACAux Pilot Contact Current Rating1.2ABranch Switch RatingBRANCH CIRCUIT DISCONNECT SWITCHCSA List File155873CSA List Std 1C22.2 No. 182.1-13CSA ListingcCSAusCurrent Interrupting RatingSWITCH RATEDFrequency60 HzHP5Impact RatingIK09Keying Position4Load Break Normal Operation45 AMaterialPOLYMaximum Operating Temperature-C60CMaximum Operating Temperature-F140FMinimum Operating Temperature-C-40CMinimum Operating Temperature-F-40FMotor Switch RatingMOTOR CIRCUIT DISCONNECT SWITCHNEMA Watertightness3RNumber Of Auxiliary Contacts+4 AUXPhase Condenser Strip Length7/8 IN OR 22 MMPhase Term Tightening Torque15 IN-LBS / 1.7 N-MPhase Term TypeSCREW TERMINALPhase Term Wire Cap Max THHN4 AWGPhase Term Wire Cap Max Type W4 AWGPhase Term Wire Cap Min THHN14 AWGPhase Term Wire Cap Min Type W14 AWGPrimary IP Rating54Prod Wire Temperature Rating60CProduct ColorBLUERated Current30 ARated Voltage480 VACShort Circuit Rating100 kA - CLOSE & WITHSTANDShort Circuit Rating Fusing100 kA 125 A (400%) RK1 NTDUl List FileE79796 VOLUME 8 SECTION 3Ul List Std 1UL 2682Ul List Std 2UL 1682Ul ListingULUl508 Pilot Rating4 @ code A600Voltage Color CodeRED

Specifications

Accessory Size3
Aux Contact Max Voltage Rating600VAC
Aux Pilot Contact Current Rating1.2A
Branch Switch RatingBRANCH CIRCUIT DISCONNECT SWITCH
CSA List File155873
CSA List Std 1C22.2 No. 182.1-13
CSA ListingcCSAus
Current Interrupting RatingSWITCH RATED
Frequency60 Hz
HP5
Impact RatingIK09
Keying Position4
Load Break Normal Operation45 A
MaterialPOLY
Maximum Operating Temperature-C60C
Maximum Operating Temperature-F140F
Minimum Operating Temperature-C-40C
Minimum Operating Temperature-F-40F
Motor Switch RatingMOTOR CIRCUIT DISCONNECT SWITCH
NEMA Watertightness3R
Number Of Auxiliary Contacts+4 AUX
Phase Condenser Strip Length7/8 IN OR 22 MM
Phase Term Tightening Torque15 IN-LBS / 1.7 N-M
Phase Term TypeSCREW TERMINAL
Phase Term Wire Cap Max THHN4 AWG
Phase Term Wire Cap Max Type W4 AWG
Phase Term Wire Cap Min THHN14 AWG
Phase Term Wire Cap Min Type W14 AWG
Primary IP Rating54
Prod Wire Temperature Rating60C
Product ColorBLUE
Rated Current30 A
Rated Voltage480 VAC
Short Circuit Rating100 kA - CLOSE & WITHSTAND
Short Circuit Rating Fusing100 kA 125 A (400%) RK1 NTD
Ul List FileE79796 VOLUME 8 SECTION 3
Ul List Std 1UL 2682
Ul List Std 2UL 1682
Ul ListingUL
Ul508 Pilot Rating4 @ code A600
Voltage Color CodeRED

33-38042-974