Action type of the contact element (acc. to IEC 60947-5-1)Snap Action SimultaneousB10d value30 Millions operationsConventional free-air thermal currentacc. to IEC 60947-5-1, q = 40 °C 10 ADegree of protectionacc. to IEC 60529 IP65Housing materialPlasticMaximum electrical switching frequency(AC-15) 3600 cycles per hour(DC-13) 3600 cycles per hourMaximum mounted auxiliary contacts1 NO, 1 NCMechanical durability0 cycleNumber and type of bottom cable glands1 x M20x1.5 - BottomPilot duty UL/CSAA600Q600Rated impulse withstand voltage6 kVRated insulation voltageacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 Vacc. to UL/CSA 600 VRated operational current AC-15(230 V AC) 3.1 A(400 V) NC 4(24 V) 10 A(130 V) 5.5 A(240 V) 3 ARated operational current DC-13(24 V) 6 A(110 V) 0.6 A(125 V) 0.55 A(250 V) 0.4 AShort-circuit protective devicesgG Type Fuses 10 A
| Action type of the contact element (acc. to IEC 60947-5-1) | Snap Action Simultaneous |
| B10d value | 30 Millions operations |
| Conventional free-air thermal current | acc. to IEC 60947-5-1, q = 40 °C 10 A |
| Degree of protection | acc. to IEC 60529 IP65 |
| Housing material | Plastic |
| Maximum electrical switching frequency | (AC-15) 3600 cycles per hour(DC-13) 3600 cycles per hour |
| Maximum mounted auxiliary contacts | 1 NO, 1 NC |
| Mechanical durability | 0 cycle |
| Number and type of bottom cable glands | 1 x M20x1.5 - Bottom |
| Pilot duty UL/CSA | A600Q600 |
| Rated impulse withstand voltage | 6 kV |
| Rated insulation voltage | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 Vacc. to UL/CSA 600 V |
| Rated operational current AC-15 | (230 V AC) 3.1 A(400 V) NC 4(24 V) 10 A(130 V) 5.5 A(240 V) 3 A |
| Rated operational current DC-13 | (24 V) 6 A(110 V) 0.6 A(125 V) 0.55 A(250 V) 0.4 A |
| Short-circuit protective devices | gG Type Fuses 10 A |