Cart
Custom content
<p>This is custom content</p>

ABB SK4-11 Signal Contact | SK4-11

$110.10
Quantity
Add to wishlist
Usually in stock

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

Guarantee safe & secure checkout

Ambient air temperatureOperation -25 . +70 C Storage -50 +80 CBV certificate1SAA937000-0201CCC certificate1SAA937003-3803Connecting capacity auxiliary circuit UL/CSAStranded 1/2x 18 ... 14 AWG Flexible 1/2x 18 ... 14 AWGContact rating UL/CSAB600 Q600Conventional free-air thermal current (Ith)10 ACSA certificate1SAA937000-1101Data sheet, technical information1SBC100173C0201Declaration of conformity - CE1SAD938504-0050 1SAD938504-0051 1SAD938505-0050Degree of protectionIP20DNV certificate1SAA937000-0301E-nummer3112322eClass7.0 27379201ETIM 4EC002498 - Accessories for low-voltage switch technologyETIM 5EC002498 - Accessories for low-voltage switch technologyETIM 6EC002498 - Accessories for low-voltage switch technologyGL certificate1SAA937000-0404GOST certificate1SAA937000-2703Number of auxiliary contacts CO SPDT0Number of auxiliary contacts NC2Number of auxiliary contacts NO2Object classification codeQProduct nameSignal ContactRated frequencyAuxiliary Circuit DC Auxiliary Circuit 50 Hz Auxiliary Circuit 60 HzRated insulation voltage (Ui)690 VRated operational current AC-15 (Ie)(24 V) 6 A (230 V) 4 A (400 V) 3 ARated operational current DC-13 (Ie)(24 V) 1 A (110 V) 0.5 A (220 V) 0,25 ARated operational voltage690 VRecommended screw driverPozidriv 2RoHS information1SAA918002-4401Short-circuit protective devicesAuxiliary Circuit - gG Type Fuses 10 AStandardsIEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 508 CSA 22.2 No. 14Suitable forMS450 MS451 MO450 MS495 MS496 MS497 MO495 MO496Suitable for product classManual Motor StarterTightening torqueAuxiliary Circuit 0.8 1.2 NmTightening torque UL/CSAAuxiliary Circuit 7 10.3 inlbUL certificateUL_E149922Wire stripping lengthAuxiliary Circuit 10 mm

Specifications

Ambient air temperatureOperation -25 . +70 C Storage -50 +80 C
BV certificate1SAA937000-0201
CCC certificate1SAA937003-3803
Connecting capacity auxiliary circuit UL/CSAStranded 1/2x 18 ... 14 AWG Flexible 1/2x 18 ... 14 AWG
Contact rating UL/CSAB600 Q600
Conventional free-air thermal current (Ith)10 A
CSA certificate1SAA937000-1101
Data sheet, technical information1SBC100173C0201
Declaration of conformity - CE1SAD938504-0050 1SAD938504-0051 1SAD938505-0050
Degree of protectionIP20
DNV certificate1SAA937000-0301
E-nummer3112322
eClass7.0 27379201
ETIM 4EC002498 - Accessories for low-voltage switch technology
ETIM 5EC002498 - Accessories for low-voltage switch technology
ETIM 6EC002498 - Accessories for low-voltage switch technology
GL certificate1SAA937000-0404
GOST certificate1SAA937000-2703
Number of auxiliary contacts CO SPDT0
Number of auxiliary contacts NC2
Number of auxiliary contacts NO2
Object classification codeQ
Product nameSignal Contact
Rated frequencyAuxiliary Circuit DC Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz
Rated insulation voltage (Ui)690 V
Rated operational current AC-15 (Ie)(24 V) 6 A (230 V) 4 A (400 V) 3 A
Rated operational current DC-13 (Ie)(24 V) 1 A (110 V) 0.5 A (220 V) 0,25 A
Rated operational voltage690 V
Recommended screw driverPozidriv 2
RoHS information1SAA918002-4401
Short-circuit protective devicesAuxiliary Circuit - gG Type Fuses 10 A
StandardsIEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 508 CSA 22.2 No. 14
Suitable forMS450 MS451 MO450 MS495 MS496 MS497 MO495 MO496
Suitable for product classManual Motor Starter
Tightening torqueAuxiliary Circuit 0.8 1.2 Nm
Tightening torque UL/CSAAuxiliary Circuit 7 10.3 inlb
UL certificateUL_E149922
Wire stripping lengthAuxiliary Circuit 10 mm

SK4-11

16 other products in the same category:

This website uses cookies to ensure you get the best experience on our website