ABS certificate1SAA963000-0104Actuator typeRotary HandleAmbient air temperature compensationYesAmpere rating UL/CSA0.4 ABV certificate1SAA963000-0202CB certificate1SAA963000-2003CCC certificate1SAA963000-3803Connecting capacity main circuit UL/CSAFlexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWGContact position indicationON / OFFConventional free-air thermal current (Ith)Main Circuit 0.4 ACountry of OriginGermany (DE)CriticalityNocUL certificatecUL_E137861Data sheet, technical information2CDC131025D0201Data sheet, technical information (Part 2)1SAM200505F0003Data sheet, technical information (Part 3)1SAM200507F0001 1SAM200507F0002 1SAM200507F0003 1SAM200508F0001 1SAM200508F0002 1SAM200508F0003Declaration of conformity - CE1SAD938516-0060Degree of protectionHousing IP20 Main Circuit Terminals IP10DNV certificate1SAA963000-0303E-nummer3111934EAC certificate1SAA963000-2701eClass7.0 27370401Electrical durability100000 cycleETIM 4EC000074 - Motor protective circuit-breakerETIM 5EC000074 - Motor protective circuit-breakerETIM 6EC000074 - Motor protection circuit-breakerGeneral use rating UL/CSA(600 V AC) 0.4 AGL certificate1SAA963000-0402GOST certificate1SAA963001-2702Lead time19 day(s)LR certificate1SAA963000-0505Made to orderNoMax operating altitude permissible2000 mMaximum operating voltage UL/CSAMain Circuit 600 V ACMechanical durability100000 cycleMounting positionPosition 1 to 6Number of poles3Object classification codeFPollution degree3Power lossat Rated Operating Conditions per Pole 0.7 ... 1.7 WProduct sales statusActiveQuote onlyNoRated frequencyMain Circuit 50 Hz Main Circuit 60 HzRated impulse withstand voltage (U imp)Main Circuit 6 kVRated instantaneous short-circuit current setting (Ii)5 ARated insulation voltage (Ui)690 VRated operational current (Ie)0.4 ARated operational current AC-3 (Ie)0.4 ARated operational power AC-3 (Pe)(400 V) Three Phase 0.09 kWRated operational voltageMain Circuit 690 V ACRated service short-circuit breaking capacity (Ics)(230 V AC)
| ABS certificate | 1SAA963000-0104 |
| Actuator type | Rotary Handle |
| Ambient air temperature compensation | Yes |
| Ampere rating UL/CSA | 0.4 A |
| BV certificate | 1SAA963000-0202 |
| CB certificate | 1SAA963000-2003 |
| CCC certificate | 1SAA963000-3803 |
| Connecting capacity main circuit UL/CSA | Flexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWG |
| Contact position indication | ON / OFF |
| Conventional free-air thermal current (Ith) | Main Circuit 0.4 A |
| Country of Origin | Germany (DE) |
| Criticality | No |
| cUL certificate | cUL_E137861 |
| Data sheet, technical information | 2CDC131025D0201 |
| Data sheet, technical information (Part 2) | 1SAM200505F0003 |
| Data sheet, technical information (Part 3) | 1SAM200507F0001 1SAM200507F0002 1SAM200507F0003 1SAM200508F0001 1SAM200508F0002 1SAM200508F0003 |
| Declaration of conformity - CE | 1SAD938516-0060 |
| Degree of protection | Housing IP20 Main Circuit Terminals IP10 |
| DNV certificate | 1SAA963000-0303 |
| E-nummer | 3111934 |
| EAC certificate | 1SAA963000-2701 |
| eClass | 7.0 27370401 |
| Electrical durability | 100000 cycle |
| ETIM 4 | EC000074 - Motor protective circuit-breaker |
| ETIM 5 | EC000074 - Motor protective circuit-breaker |
| ETIM 6 | EC000074 - Motor protection circuit-breaker |
| General use rating UL/CSA | (600 V AC) 0.4 A |
| GL certificate | 1SAA963000-0402 |
| GOST certificate | 1SAA963001-2702 |
| Lead time | 19 day(s) |
| LR certificate | 1SAA963000-0505 |
| Made to order | No |
| Max operating altitude permissible | 2000 m |
| Maximum operating voltage UL/CSA | Main Circuit 600 V AC |
| Mechanical durability | 100000 cycle |
| Mounting position | Position 1 to 6 |
| Number of poles | 3 |
| Object classification code | F |
| Pollution degree | 3 |
| Power loss | at Rated Operating Conditions per Pole 0.7 ... 1.7 W |
| Product sales status | Active |
| Quote only | No |
| Rated frequency | Main Circuit 50 Hz Main Circuit 60 Hz |
| Rated impulse withstand voltage (U imp) | Main Circuit 6 kV |
| Rated instantaneous short-circuit current setting (Ii) | 5 A |
| Rated insulation voltage (Ui) | 690 V |
| Rated operational current (Ie) | 0.4 A |
| Rated operational current AC-3 (Ie) | 0.4 A |
| Rated operational power AC-3 (Pe) | (400 V) Three Phase 0.09 kW |
| Rated operational voltage | Main Circuit 690 V AC |
| Rated service short-circuit breaking capacity (Ics) | (230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 30 kA (500 V AC) 30 kA (690 V AC) 30 kA |
| Rated ultimate short-circuit breaking capacity (Icu) | (230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 30 kA (500 V AC) 30 kA (690 V AC) 30 kA |
| Recommended screw driver | Pozidriv 2 |
| Resistance to shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to vibrations acc. to IEC 60068-2-6 | 5g / 3 ... 150 Hz |
| RMRS certificate | 1SAA918000-0703 |
| RoHS information | 1SAA963001-4407 |
| RoHS status | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| Setting range | 0.25 ... 0.4 A |
| Standards | IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 |
| Tightening torque | Main Circuit 0.8 ... 1.2 Nm |
| Tightening torque UL/CSA | Main Circuit 10 inlb |
| UL certificate | UL_E137861 |
| Wire stripping length | Main Circuit 9 mm |