Cart
Custom content
<p>This is custom content</p>

HPS DM145BK DIT 145kVA 208-480 AL Drive Isolation Transformers

$7,170.73
Quantity
Add to wishlist
Usually in stock

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

Guarantee safe & secure checkout

ApprovalCSA, ULDrive isolation transformer3ph 145kVA 208V-480Y/277V 60Hz ALDutyGeneral dutyEfficiency regulationNot specified (USA)Enclosure dimensions41in/1042mm(H), 32in/813mm(W), 25.5in/648mm(D)Enclosure finishANSI 61 grey, UL50Enclosure IR windowNoEnclosure PN (NPL)NH4-N3REnclosure typeType 3R / IP24Frequency60HzImpedance (std)3% - 6%Insulation class220°CMaterialAluminumMotor HPNot SelectedNameplateHPS standardNet weight (NPL)820 lb / 372 kgNumber of secondaries1 (6-pulse)PhaseThree phasePrimary connectionDeltaPrimary FCAN (NPL)1x5%Primary FCBN (NPL)1x5%Primary termination (NPL)Mounting padsPrimary voltage208DRating145 kVASecondary connectionWye-NSecondary termination (NPL)Mechanical lugsSecondary voltage480Y/277Seismic complianceIBC 2018 (Sds=2.0, z/h=0, lp=1.5)Sound level50 dBA (NEMA ST-20)Standard kVA145Temperature rise150°CThermal protective deviceNormally closed (all coils) thermostats with 200°C setpoint, typically built to orderVector configurationYNd1 (-30°)

Specifications

ApprovalCSA, UL
Drive isolation transformer3ph 145kVA 208V-480Y/277V 60Hz AL
DutyGeneral duty
Efficiency regulationNot specified (USA)
Enclosure dimensions41in/1042mm(H), 32in/813mm(W), 25.5in/648mm(D)
Enclosure finishANSI 61 grey, UL50
Enclosure IR windowNo
Enclosure PN (NPL)NH4-N3R
Enclosure typeType 3R / IP24
Frequency60Hz
Impedance (std)3% - 6%
Insulation class220°C
MaterialAluminum
Motor HPNot Selected
NameplateHPS standard
Net weight (NPL)820 lb / 372 kg
Number of secondaries1 (6-pulse)
PhaseThree phase
Primary connectionDelta
Primary FCAN (NPL)1x5%
Primary FCBN (NPL)1x5%
Primary termination (NPL)Mounting pads
Primary voltage208D
Rating145 kVA
Secondary connectionWye-N
Secondary termination (NPL)Mechanical lugs
Secondary voltage480Y/277
Seismic complianceIBC 2018 (Sds=2.0, z/h=0, lp=1.5)
Sound level50 dBA (NEMA ST-20)
Standard kVA145
Temperature rise150°C
Thermal protective deviceNormally closed (all coils) thermostats with 200°C setpoint, typically built to order
Vector configurationYNd1 (-30°)

DM145BK

16 other products in the same category:

This website uses cookies to ensure you get the best experience on our website