ABS certificate1SAA963000-0103Actuator typeRotary HandleAmbient air temperature compensationYesAmpere rating UL/CSA16 ABV certificate1SAA963000-0202CB certificate1SAA963000-2002CCC certificate1SAA963000-3803Connecting capacity main circuit UL/CSAFlexible 1/2x 16-8 AWG Stranded 1/2x 16-8 AWGContact position indicationON / OFFConventional free-air thermal current (Ith)Main Circuit 16 AcUL certificatecUL_E137861Data sheet, technical information2CDC131025D0201Data sheet, technical information (Part 2)1SAM200505F0011Data sheet, technical information (Part 3)1SAM200507F0001 1SAM200507F0002 1SAM200507F0003 1SAM200508F0001 1SAM200508F0002 1SAM200508F0003Declaration of conformity - CE1SAD938516-0060Degree of protectionIP20DNV certificate1SAA963000-0302eClass7.0 27370401Electrical durability100000 cycleETIM 4EC000074 - Motor protective circuit-breakerETIM 5EC000074 - Motor protective circuit-breakerETIM 6EC000074 - Motor protection circuit-breakerGeneral use rating UL/CSA(600 V AC) 16 AGL certificate1SAA963000-0402GOST certificate1SAA937000-2703LR certificate1SAA963000-0505Max operating altitude permissible2000 mMaximum operating voltage UL/CSAMain Circuit 600 V ACMechanical durability100000 cycleMounting positionPosition 1 to 6Number of poles3Object classification codeFOperational current1.6 AOperational voltage690 V ACPoles3Pollution degree3Rated frequencyMain Circuit 50 Hz Main Circuit 60 HzRated impulse withstand voltage (U imp)Main Circuit 6 kVRated instantaneous short-circuit current setting (Ii)240 ARated insulation voltage (Ui)690 VRated operational current (Ie)16 ARated operational current AC-3 (Ie)16 ARated operational power AC-3 (Pe)(400 V) Three Phase 7.5 kWRated operational voltageMain Circuit 690 V ACRated service short-circuit breaking capacity (Ics)(230 V AC) 16 kA (400 V AC) 16 kA (440 V AC) 4 kA (500 V AC) 4 kA (690 V AC) 2 kARated ultimate short-circuit breaking capacity (Icu)(230 V AC) 16 kA (400 V AC) 16 kA (440 V AC) 4 kA (500 V AC) 4 kA (690 V AC) 2 kAR
| ABS certificate | 1SAA963000-0103 |
| Actuator type | Rotary Handle |
| Ambient air temperature compensation | Yes |
| Ampere rating UL/CSA | 16 A |
| BV certificate | 1SAA963000-0202 |
| CB certificate | 1SAA963000-2002 |
| CCC certificate | 1SAA963000-3803 |
| Connecting capacity main circuit UL/CSA | Flexible 1/2x 16-8 AWG Stranded 1/2x 16-8 AWG |
| Contact position indication | ON / OFF |
| Conventional free-air thermal current (Ith) | Main Circuit 16 A |
| cUL certificate | cUL_E137861 |
| Data sheet, technical information | 2CDC131025D0201 |
| Data sheet, technical information (Part 2) | 1SAM200505F0011 |
| Data sheet, technical information (Part 3) | 1SAM200507F0001 1SAM200507F0002 1SAM200507F0003 1SAM200508F0001 1SAM200508F0002 1SAM200508F0003 |
| Declaration of conformity - CE | 1SAD938516-0060 |
| Degree of protection | IP20 |
| DNV certificate | 1SAA963000-0302 |
| eClass | 7.0 27370401 |
| Electrical durability | 100000 cycle |
| ETIM 4 | EC000074 - Motor protective circuit-breaker |
| ETIM 5 | EC000074 - Motor protective circuit-breaker |
| ETIM 6 | EC000074 - Motor protection circuit-breaker |
| General use rating UL/CSA | (600 V AC) 16 A |
| GL certificate | 1SAA963000-0402 |
| GOST certificate | 1SAA937000-2703 |
| LR certificate | 1SAA963000-0505 |
| Max operating altitude permissible | 2000 m |
| Maximum operating voltage UL/CSA | Main Circuit 600 V AC |
| Mechanical durability | 100000 cycle |
| Mounting position | Position 1 to 6 |
| Number of poles | 3 |
| Object classification code | F |
| Operational current | 1.6 A |
| Operational voltage | 690 V AC |
| Poles | 3 |
| Pollution degree | 3 |
| Rated frequency | Main Circuit 50 Hz Main Circuit 60 Hz |
| Rated impulse withstand voltage (U imp) | Main Circuit 6 kV |
| Rated instantaneous short-circuit current setting (Ii) | 240 A |
| Rated insulation voltage (Ui) | 690 V |
| Rated operational current (Ie) | 16 A |
| Rated operational current AC-3 (Ie) | 16 A |
| Rated operational power AC-3 (Pe) | (400 V) Three Phase 7.5 kW |
| Rated operational voltage | Main Circuit 690 V AC |
| Rated service short-circuit breaking capacity (Ics) | (230 V AC) 16 kA (400 V AC) 16 kA (440 V AC) 4 kA (500 V AC) 4 kA (690 V AC) 2 kA |
| Rated ultimate short-circuit breaking capacity (Icu) | (230 V AC) 16 kA (400 V AC) 16 kA (440 V AC) 4 kA (500 V AC) 4 kA (690 V AC) 2 kA |
| Recommended screw driver | Pozidriv 2 |
| Resistance to shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to vibrations acc. to IEC 60068-2-6 | 5g / 3 ... 150 Hz |
| RMRS certificate | 1SAA918000-0703 |
| RoHS information | 1SAA963001-4407 |
| RoHS status | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| Setting range | 10 ... 16 A |
| Tightening torque | Main Circuit 0.8 ... 1.2 Nm |
| Tightening torque UL/CSA | Main Circuit 10 inlb |
| UL certificate | UL_E137861 |
| Wire stripping length | Main Circuit 9 mm |