Actuator typeRotary HandleAmbient air temperature compensationYesAmpere rating UL/CSA0.63 AATEX certificate1SAA918000-3903BV certificate1SAA918000-0204CB certificate1SAA918000-2002CCC certificate1SAA918000-3806Connecting capacity main circuit UL/CSAFlexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWGContact position indicationON / OFFConventional free-air thermal current (Ith)Main Circuit 0.63 AcUL certificatecUL_E137861 cUL_E345003Data sheet, technical information2CDC131046D0201Data sheet, technical information (Part 2)1SAM100513F0004Declaration of conformity - CE1SAD938513-0003Degree of protectionIP20DNV certificate1SAA918000-0305eClass7.0 27370401Electrical durability50000 cycleETIM 4EC000074 - Motor protective circuit-breakerETIM 5EC000074 - Motor protective circuit-breakerETIM 6EC000074 - Motor protection circuit-breakerGL certificate1SAA918000-0403GOST certificate1SAA918000-2703LR certificate1SAA918000-0503Max operating altitude permissible2000 mMaximum operating voltage UL/CSAMain Circuit 600 V ACMechanical durability100000 cycleMounting positionPosition 1 to 6Number of poles3Object classification codeFPollution degree3Power lossat Rated Operating Conditions per Pole 0.8 ... 2.1 WRated frequencyMain Circuit 50 Hz Main Circuit 60 HzRated impulse withstand voltage (U imp)Main Circuit 6 kVRated instantaneous short-circuit current setting (Ii)6.1 ARated insulation voltage (Ui)690 VRated operational current (Ie)0.63 ARated operational current AC-3 (Ie)0.63 ARated operational power AC-3 (Pe)(400 V) Three Phase 0.12 kWRated operational voltageMain Circuit 690 V AC Main Circuit 440 V DCRated service short-circuit breaking capacity (Ics)(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kARated ultimate short-circuit breaking capacity (Icu)(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kARecommended screw driverM3.5 Pozidriv 2Resistance to shock acc. to IEC 60068-2-2711 ms Pulse 15gResistance to vibr

Specifications

Actuator typeRotary Handle
Ambient air temperature compensationYes
Ampere rating UL/CSA0.63 A
ATEX certificate1SAA918000-3903
BV certificate1SAA918000-0204
CB certificate1SAA918000-2002
CCC certificate1SAA918000-3806
Connecting capacity main circuit UL/CSAFlexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWG
Contact position indicationON / OFF
Conventional free-air thermal current (Ith)Main Circuit 0.63 A
cUL certificatecUL_E137861 cUL_E345003
Data sheet, technical information2CDC131046D0201
Data sheet, technical information (Part 2)1SAM100513F0004
Declaration of conformity - CE1SAD938513-0003
Degree of protectionIP20
DNV certificate1SAA918000-0305
eClass7.0 27370401
Electrical durability50000 cycle
ETIM 4EC000074 - Motor protective circuit-breaker
ETIM 5EC000074 - Motor protective circuit-breaker
ETIM 6EC000074 - Motor protection circuit-breaker
GL certificate1SAA918000-0403
GOST certificate1SAA918000-2703
LR certificate1SAA918000-0503
Max operating altitude permissible2000 m
Maximum operating voltage UL/CSAMain Circuit 600 V AC
Mechanical durability100000 cycle
Mounting positionPosition 1 to 6
Number of poles3
Object classification codeF
Pollution degree3
Power lossat Rated Operating Conditions per Pole 0.8 ... 2.1 W
Rated frequencyMain Circuit 50 Hz Main Circuit 60 Hz
Rated impulse withstand voltage (U imp)Main Circuit 6 kV
Rated instantaneous short-circuit current setting (Ii)6.1 A
Rated insulation voltage (Ui)690 V
Rated operational current (Ie)0.63 A
Rated operational current AC-3 (Ie)0.63 A
Rated operational power AC-3 (Pe)(400 V) Three Phase 0.12 kW
Rated operational voltageMain Circuit 690 V AC Main Circuit 440 V DC
Rated service short-circuit breaking capacity (Ics)(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA
Rated ultimate short-circuit breaking capacity (Icu)(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA
Recommended screw driverM3.5 Pozidriv 2
Resistance to shock acc. to IEC 60068-2-2711 ms Pulse 15g
Resistance to vibrations acc. to IEC 60068-2-65g / 10 ... 150 Hz
RINA certificate1SAA918000-0803
RMRS certificate1SAA918000-0703
RoHS information1SAA918001-4401
RoHS statusFollowing EU Directive 2002/95/EC August 18, 2005 and amendment
Setting range0.4 ... 0.63 A
StandardsIEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1
Tightening torqueMain Circuit 1.4 Nm
Tightening torque UL/CSAAuxiliary Circuit 7 inlb Main Circuit 14 inlb
UL certificateUL_E137861 UL_E345003
Wire stripping lengthAuxiliary Circuit 8 mm Main Circuit 10 mm