Actuator typeRotary HandleAmbient air temperature compensationYesAmpere rating UL/CSA1.6 AATEX certificate1SAA918000-3903BV certificate1SAA918000-0204CB certificate1SAA918000-2002CCC certificate1SAA918000-3806Connecting capacity main circuit UL/CSAFlexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWGContact position indicationON / OFFConventional free-air thermal current (Ith)Main Circuit 1.6 ACountry of OriginGermany (DE)cUL certificatecUL_E137861 cUL_E345003Data sheet, technical information2CDC131046D0201Data sheet, technical information (Part 2)1SAM100513F0006Declaration of conformity - CE1SAD938513-0003Degree of protectionIP20DNV certificate1SAA918000-0305eClass7.0 27370401Electrical durability50000 cycleETIM 4EC000074 - Motor protective circuit-breakerETIM 5EC000074 - Motor protective circuit-breakerETIM 6EC000074 - Motor protection circuit-breakerGL certificate1SAA918000-0403GOST certificate1SAA918000-2703Horsepower rating UL/CSA(440 ... 480 V AC) Three Phase 0.75 Hp (550 ... 600 V AC) Three Phase 0.75 HpLead time0 day(s)LR certificate1SAA918000-0503Made to orderNoMax operating altitude permissible2000 mMaximum operating voltage UL/CSAMain Circuit 600 V ACMechanical durability100000 cycleMounted auxiliary contacts1 NO, 1 NCMounting positionPosition 1 to 6Number of auxiliary contacts NC1Number of auxiliary contacts NO1Number of poles3Object classification codeFPollution degree3Power lossat Rated Operating Conditions per Pole 0.8 ... 2.1 WProduct sales statusInactiveQuote onlyNoRated frequencyMain Circuit 50 Hz Main Circuit 60 HzRated impulse withstand voltage (U imp)Main Circuit 6 kVRated instantaneous short-circuit current setting (Ii)18.4 ARated insulation voltage (Ui)690 VRated operational current (Ie)1.6 ARated operational current AC-3 (Ie)1.6 ARated operational power AC-3 (Pe)(400 V) Three Phase 0.55 kWRated operational voltageMain Circuit 690 V AC Main Circuit 440 V DCRated service short-circuit breaking capacity (Ics)(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC
| Actuator type | Rotary Handle |
| Ambient air temperature compensation | Yes |
| Ampere rating UL/CSA | 1.6 A |
| ATEX certificate | 1SAA918000-3903 |
| BV certificate | 1SAA918000-0204 |
| CB certificate | 1SAA918000-2002 |
| CCC certificate | 1SAA918000-3806 |
| Connecting capacity main circuit UL/CSA | Flexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWG |
| Contact position indication | ON / OFF |
| Conventional free-air thermal current (Ith) | Main Circuit 1.6 A |
| Country of Origin | Germany (DE) |
| cUL certificate | cUL_E137861 cUL_E345003 |
| Data sheet, technical information | 2CDC131046D0201 |
| Data sheet, technical information (Part 2) | 1SAM100513F0006 |
| Declaration of conformity - CE | 1SAD938513-0003 |
| Degree of protection | IP20 |
| DNV certificate | 1SAA918000-0305 |
| eClass | 7.0 27370401 |
| Electrical durability | 50000 cycle |
| ETIM 4 | EC000074 - Motor protective circuit-breaker |
| ETIM 5 | EC000074 - Motor protective circuit-breaker |
| ETIM 6 | EC000074 - Motor protection circuit-breaker |
| GL certificate | 1SAA918000-0403 |
| GOST certificate | 1SAA918000-2703 |
| Horsepower rating UL/CSA | (440 ... 480 V AC) Three Phase 0.75 Hp (550 ... 600 V AC) Three Phase 0.75 Hp |
| Lead time | 0 day(s) |
| LR certificate | 1SAA918000-0503 |
| Made to order | No |
| Max operating altitude permissible | 2000 m |
| Maximum operating voltage UL/CSA | Main Circuit 600 V AC |
| Mechanical durability | 100000 cycle |
| Mounted auxiliary contacts | 1 NO, 1 NC |
| Mounting position | Position 1 to 6 |
| Number of auxiliary contacts NC | 1 |
| Number of auxiliary contacts NO | 1 |
| Number of poles | 3 |
| Object classification code | F |
| Pollution degree | 3 |
| Power loss | at Rated Operating Conditions per Pole 0.8 ... 2.1 W |
| Product sales status | Inactive |
| Quote only | No |
| Rated frequency | Main Circuit 50 Hz Main Circuit 60 Hz |
| Rated impulse withstand voltage (U imp) | Main Circuit 6 kV |
| Rated instantaneous short-circuit current setting (Ii) | 18.4 A |
| Rated insulation voltage (Ui) | 690 V |
| Rated operational current (Ie) | 1.6 A |
| Rated operational current AC-3 (Ie) | 1.6 A |
| Rated operational power AC-3 (Pe) | (400 V) Three Phase 0.55 kW |
| Rated operational voltage | Main Circuit 690 V AC Main Circuit 440 V DC |
| Rated service short-circuit breaking capacity (Ics) | (230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) | (230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA |
| Recommended screw driver | M3.5 Pozidriv 2 |
| Resistance to shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Resistance to vibrations acc. to IEC 60068-2-6 | 5g / 10 ... 150 Hz |
| RINA certificate | 1SAA918000-0803 |
| RMRS certificate | 1SAA918000-0703 |
| RoHS information | 1SAA918001-4401 |
| RoHS status | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| Setting range | 1 ... 1.6 A |
| Standards | IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 508 CSA 22.2 No. 14 |
| Tightening torque | Main Circuit 1.4 Nm |
| Tightening torque UL/CSA | Auxiliary Circuit 7 inlb Main Circuit 14 inlb |
| UL certificate | UL_E137861 UL_E345003 |
| Wire stripping length | Auxiliary Circuit 8 mm Main Circuit 10 mm |