Agency ApprovalsCSAEEVAgency approvalsCSA EEVAmbient Temperature40°CAmbient temperature (°C)40Auxillary BoxNoAuxillaryBoxAuxillary boxNo auxillary boxAuxillary Box Lead TerminationNoneBase IndicatorNoMountingBase indicatorNo mountingBearing Grease TypePolyrexEM(-20F+300F)Bearing grease typePolyrex EM (-20F +300F)BlowerNoneBreak-Down Torque65.1LB-FTBreak-down torque65.1 lb-ftConduit Box MaterialSteelConstant Torque Speed Range30Constant torque speed range30Current @ Voltage6.800A@460.0VCurrent @ voltage6.800 A @ 460.0 VDesign CodeADesign codeADrip CoverNoDripCoverDrip coverNo drip coverDuty RatingCONTDuty ratingCONTEfficiency @ 100% Load89.5%Efficiency @ 100% load89.5 %Electrically Isolated BearingNotElectricallyIsolatedElectrically isolated bearingNot electrically isolatedEnclosureXPFCFeedback DeviceNOFEEDBACKFeedback deviceNo feedbackFrame184TCFrame MaterialSteelFrame materialSteelFrequency50.00 HzFull Load Torque0LB-FTFull load torque0 lb-ftHeater IndicatorNoHeaterHeater indicatorNo heaterHigh Voltage Full Load Amps5.6aHigh voltage full load amps5.6 aHP5 HpInsulation ClassFInsulation classFInverter CodeInverterDutyInverter codeInverter dutyIP RatingNONEKVA CodeLKVA codeLLifting LugsNoLiftingLugsLifting lugsNo lifting lugsLine-line res @ 25° C1.91 Ohms A Ph / 0 Ohms B PhLine-Line Res. @ 25° C1.91OhmsAPh/0OhmsBPhLocked Bearing IndicatorLockedBearingLocked bearing indicatorLocked bearingLocked-Rotor Torque43.59LB-FTLocked-rotor torque43.59 lb-ftMax Speed2700 RPMMotor Lead TerminationFlyingLeadsMotor lead terminationFlying leadsMotor Letter TypeThreePhaseMotor letter typeThree phaseMotor StandardsNEMAMotor standardsNEMAMotor Type3646MMotor type3646MMotor Weight118Mounting ArrangementF1Mounting arrangementF1No-Load Current0ANo-load current0 ANumber of Poles4Number of poles4Output @ Frequency3.000HP@50HZOutput @ frequency3.000 HP @ 50 HZOverall Length20.36 inPhase3Power Factor74Power factor74Product FamilyGeneralPurposeProduct familyGeneral PurposePull-Up Torque35.75LB-
| Agency Approvals | CSAEEV |
| Agency approvals | CSA EEV |
| Ambient Temperature | 40°C |
| Ambient temperature (°C) | 40 |
| Auxillary Box | NoAuxillaryBox |
| Auxillary box | No auxillary box |
| Auxillary Box Lead Termination | None |
| Base Indicator | NoMounting |
| Base indicator | No mounting |
| Bearing Grease Type | PolyrexEM(-20F+300F) |
| Bearing grease type | Polyrex EM (-20F +300F) |
| Blower | None |
| Break-Down Torque | 65.1LB-FT |
| Break-down torque | 65.1 lb-ft |
| Conduit Box Material | Steel |
| Constant Torque Speed Range | 30 |
| Constant torque speed range | 30 |
| Current @ Voltage | 6.800A@460.0V |
| Current @ voltage | 6.800 A @ 460.0 V |
| Design Code | A |
| Design code | A |
| Drip Cover | NoDripCover |
| Drip cover | No drip cover |
| Duty Rating | CONT |
| Duty rating | CONT |
| Efficiency @ 100% Load | 89.5% |
| Efficiency @ 100% load | 89.5 % |
| Electrically Isolated Bearing | NotElectricallyIsolated |
| Electrically isolated bearing | Not electrically isolated |
| Enclosure | XPFC |
| Feedback Device | NOFEEDBACK |
| Feedback device | No feedback |
| Frame | 184TC |
| Frame Material | Steel |
| Frame material | Steel |
| Frequency | 50.00 Hz |
| Full Load Torque | 0LB-FT |
| Full load torque | 0 lb-ft |
| Heater Indicator | NoHeater |
| Heater indicator | No heater |
| High Voltage Full Load Amps | 5.6a |
| High voltage full load amps | 5.6 a |
| HP | 5 Hp |
| Insulation Class | F |
| Insulation class | F |
| Inverter Code | InverterDuty |
| Inverter code | Inverter duty |
| IP Rating | NONE |
| KVA Code | L |
| KVA code | L |
| Lifting Lugs | NoLiftingLugs |
| Lifting lugs | No lifting lugs |
| Line-line res @ 25° C | 1.91 Ohms A Ph / 0 Ohms B Ph |
| Line-Line Res. @ 25° C | 1.91OhmsAPh/0OhmsBPh |
| Locked Bearing Indicator | LockedBearing |
| Locked bearing indicator | Locked bearing |
| Locked-Rotor Torque | 43.59LB-FT |
| Locked-rotor torque | 43.59 lb-ft |
| Max Speed | 2700 RPM |
| Motor Lead Termination | FlyingLeads |
| Motor lead termination | Flying leads |
| Motor Letter Type | ThreePhase |
| Motor letter type | Three phase |
| Motor Standards | NEMA |
| Motor standards | NEMA |
| Motor Type | 3646M |
| Motor type | 3646M |
| Motor Weight | 118 |
| Mounting Arrangement | F1 |
| Mounting arrangement | F1 |
| No-Load Current | 0A |
| No-load current | 0 A |
| Number of Poles | 4 |
| Number of poles | 4 |
| Output @ Frequency | 3.000HP@50HZ |
| Output @ frequency | 3.000 HP @ 50 HZ |
| Overall Length | 20.36 in |
| Phase | 3 |
| Power Factor | 74 |
| Power factor | 74 |
| Product Family | GeneralPurpose |
| Product family | General Purpose |
| Pull-Up Torque | 35.75LB-FT |
| Pull-up torque | 35.75 lb-ft |
| Pulley Face Code | C-Face |
| Pulley face code | C-face |
| Rodent Screen | None |
| Service Factor | 1 |
| Service factor | 1.00 |
| Shaft Diameter | 1.125 in |
| Shaft Ground Indicator | NoShaftGrounding |
| Shaft ground indicator | No shaft grounding |
| Shaft Rotation | Reversible |
| Shaft rotation | Reversible |
| Speed | 1750 RPM |
| Speed Code | SingleSpeed |
| Speed code | Single speed |
| Start Configuration | DOL |
| Start configuration | DOL |
| Starting Current | 57.03A |
| Starting current | 57.03 A |
| Starting Method | Directonline |
| Starting method | Direct on line |
| Synchronous RPM | 1800 |
| Synchronous Speed @ Frequency | 1800RPM@60HZ |
| Synchronous speed @ frequency | 1800 RPM @ 60 HZ |
| Temp rise @ rated load | 42° C |
| Temp. Rise @ Rated Load | 42°C |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | NormallyClosedThermostat |
| Thermal device - winding | Normally closed thermostat |
| Vibration Sensor Indicator | NoVibrationSensor |
| Vibration sensor indicator | No vibration sensor |
| Voltage | 230/460 |
| Voltage @ Frequency | 380.0V@50HZ |
| Voltage @ frequency | 380.0 V @ 50 HZ |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Class and Group | CLIGPD;CLIIGPF, G |
| XP class and group | CLI GP D; CLII GP F,G |
| XP Division | DivisionI |
| XP division | Division I |
| XP Temp Code | T3C |
| XP temp code | T3C |