Agency ApprovalsCSAEEVAmbient Temperature40°CAuxillary BoxNoAuxillaryBoxAuxillary Box Lead TerminationNoneBase IndicatorRigidBearing Grease TypePolyrexEM(-20F+300F)BlowerNoneBreak-Down Torque80.9LB-FTConduit Box MaterialCast IronCurrent @ Voltage24.400A@230.0VDesign CodeBDrip CoverNoDripCoverDuty RatingCONTEfficiency @ 100% Load91.7%Electrically Isolated BearingNotElectricallyIsolatedEnclosureTEFCFeedback DeviceNOFEEDBACKFrame215TFrame MaterialIronFrequency60.00HzFull Load Torque0LB-FTHeater IndicatorNoHeaterHigh Voltage Full Load Amps12.2aHP10Hz60Insulation ClassHInverter CodeInverterReadyIP RatingNONEKVA CodeHLifting LugsStandardLiftingLugsLine-Line Res. @ 25° C1.08OhmsAPh/0OhmsBPhLocked Bearing IndicatorLockedBearingLocked-Rotor Torque52.6LB-FTMotor Lead TerminationFlyingLeadsMotor Letter TypeThreePhaseMotor StandardsNEMAMotor Type0748MMotor Weight232Mounting ArrangementF1No-Load Current0ANumber of Poles4Output @ Frequency10.000HP@60HZOverall Length18.45INPhase3Power Factor83Product FamilyGeneralPurposePull-Up Torque40.2LB-FTPulley Face CodeStandardRodent ScreenNoneRPM1700 - 1800Service Factor1.15Shaft Diameter1.375INShaft Ground IndicatorShaftGroundingShaft RotationReversibleSpeed1760rpmSpeed CodeSingleSpeedStart ConfigurationDOLStarting Current81AStarting MethodDirectonlineSynchronous RPM1800Synchronous Speed @ Frequency1800RPM@60HZTemp. Rise @ Rated Load64°CTemp. Rise @ S.F. Load80°CThermal Device - BearingNoneThermal Device - WindingNoneVibration Sensor IndicatorNoVibrationSensorVoltage230/460Voltage @ Frequency230.0V@60HZWinding Thermal 1NoneWinding Thermal 2NoneXP Class and GroupNoneXP DivisionNotApplicable
| Agency Approvals | CSAEEV |
| Ambient Temperature | 40°C |
| Auxillary Box | NoAuxillaryBox |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | PolyrexEM(-20F+300F) |
| Blower | None |
| Break-Down Torque | 80.9LB-FT |
| Conduit Box Material | Cast Iron |
| Current @ Voltage | 24.400A@230.0V |
| Design Code | B |
| Drip Cover | NoDripCover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 91.7% |
| Electrically Isolated Bearing | NotElectricallyIsolated |
| Enclosure | TEFC |
| Feedback Device | NOFEEDBACK |
| Frame | 215T |
| Frame Material | Iron |
| Frequency | 60.00Hz |
| Full Load Torque | 0LB-FT |
| Heater Indicator | NoHeater |
| High Voltage Full Load Amps | 12.2a |
| HP | 10 |
| Hz | 60 |
| Insulation Class | H |
| Inverter Code | InverterReady |
| IP Rating | NONE |
| KVA Code | H |
| Lifting Lugs | StandardLiftingLugs |
| Line-Line Res. @ 25° C | 1.08OhmsAPh/0OhmsBPh |
| Locked Bearing Indicator | LockedBearing |
| Locked-Rotor Torque | 52.6LB-FT |
| Motor Lead Termination | FlyingLeads |
| Motor Letter Type | ThreePhase |
| Motor Standards | NEMA |
| Motor Type | 0748M |
| Motor Weight | 232 |
| Mounting Arrangement | F1 |
| No-Load Current | 0A |
| Number of Poles | 4 |
| Output @ Frequency | 10.000HP@60HZ |
| Overall Length | 18.45IN |
| Phase | 3 |
| Power Factor | 83 |
| Product Family | GeneralPurpose |
| Pull-Up Torque | 40.2LB-FT |
| Pulley Face Code | Standard |
| Rodent Screen | None |
| RPM | 1700 - 1800 |
| Service Factor | 1.15 |
| Shaft Diameter | 1.375IN |
| Shaft Ground Indicator | ShaftGrounding |
| Shaft Rotation | Reversible |
| Speed | 1760rpm |
| Speed Code | SingleSpeed |
| Start Configuration | DOL |
| Starting Current | 81A |
| Starting Method | Directonline |
| Synchronous RPM | 1800 |
| Synchronous Speed @ Frequency | 1800RPM@60HZ |
| Temp. Rise @ Rated Load | 64°C |
| Temp. Rise @ S.F. Load | 80°C |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | NoVibrationSensor |
| Voltage | 230/460 |
| Voltage @ Frequency | 230.0V@60HZ |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Class and Group | None |
| XP Division | NotApplicable |