Agency ApprovalsURAmbient Temperature40°CAuxillary BoxNoAuxillaryBoxAuxillary Box Lead TerminationNoneBase IndicatorRigidBearing Grease TypePolyrexEM(-20F+300F)BlowerNoneBreak-Down Torque14.6LB-FTConstant Torque Speed Range6Current @ Voltage3.000A@230.0VDesign CodeBDrip CoverNoDripCoverDuty RatingCONTEfficiency @ 100% Load85.5%Electrically Isolated BearingNotElectricallyIsolatedEnclosureTEFCFeedback DeviceNOFEEDBACKFrame143TCFrame MaterialSteelFrequency60.00HzFront Face CodeStandardFront Shaft IndicatorNoneFull Load Torque0LB-FTHeater IndicatorNoHeaterHigh Voltage Full Load Amps1.5aHP1Hz60Insulation ClassFInverter CodeInverterDutyKVA CodeLLifting LugsNoLiftingLugsLine-Line Res. @ 25° C16.049OhmsAPh/0OhmsBPhLocked Bearing IndicatorLockedBearingLocked-Rotor Torque9.17LB-FTMax Speed2700rpmMotor Lead ExitKoBoxMotor Lead Quantity/Wire Size9@18AWGMotor Lead TerminationFlyingLeadsMotor Letter TypeThreePhaseMotor StandardsNEMAMotor Type3520MMounting ArrangementF1No-Load Current0ANumber of Poles4Output @ Frequency1.000HP@60HZOverall Length13.35INPhase3Power Factor71Product FamilyDirtyDutyPlusPull-Up Torque7.57LB-FTPulley End Bearing TypeSealedBearingPulley Face CodeC-FacePulley Shaft IndicatorStandardRodent ScreenNoneRoHS StatusROHSCOMPLIANTRPM1700 - 1800Service Factor1.15Shaft Diameter0.875INShaft Extension LocationPulleyEndShaft Ground IndicatorNoShaftGroundingShaft RotationReversibleShaft Slinger IndicatorNoSlingerSpeed1760rpmSpeed CodeSingleSpeedStart ConfigurationDOLStarting Current14.6AStarting MethodDirectonlineSynchronous Speed @ Frequency1800RPM@60HZTemp. Rise @ Rated Load36°CTemp. Rise @ S.F. Load41°CThermal Device - BearingNoneThermal Device - WindingNoneVibration Sensor IndicatorNoVibrationSensorVoltage230/460Voltage @ Frequency460.0V@60HZWinding Thermal 1NoneWinding Thermal 2NoneXP Class and GroupNoneXP DivisionNotApplicable
| Agency Approvals | UR |
| Ambient Temperature | 40°C |
| Auxillary Box | NoAuxillaryBox |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | PolyrexEM(-20F+300F) |
| Blower | None |
| Break-Down Torque | 14.6LB-FT |
| Constant Torque Speed Range | 6 |
| Current @ Voltage | 3.000A@230.0V |
| Design Code | B |
| Drip Cover | NoDripCover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 85.5% |
| Electrically Isolated Bearing | NotElectricallyIsolated |
| Enclosure | TEFC |
| Feedback Device | NOFEEDBACK |
| Frame | 143TC |
| Frame Material | Steel |
| Frequency | 60.00Hz |
| Front Face Code | Standard |
| Front Shaft Indicator | None |
| Full Load Torque | 0LB-FT |
| Heater Indicator | NoHeater |
| High Voltage Full Load Amps | 1.5a |
| HP | 1 |
| Hz | 60 |
| Insulation Class | F |
| Inverter Code | InverterDuty |
| KVA Code | L |
| Lifting Lugs | NoLiftingLugs |
| Line-Line Res. @ 25° C | 16.049OhmsAPh/0OhmsBPh |
| Locked Bearing Indicator | LockedBearing |
| Locked-Rotor Torque | 9.17LB-FT |
| Max Speed | 2700rpm |
| Motor Lead Exit | KoBox |
| Motor Lead Quantity/Wire Size | 9@18AWG |
| Motor Lead Termination | FlyingLeads |
| Motor Letter Type | ThreePhase |
| Motor Standards | NEMA |
| Motor Type | 3520M |
| Mounting Arrangement | F1 |
| No-Load Current | 0A |
| Number of Poles | 4 |
| Output @ Frequency | 1.000HP@60HZ |
| Overall Length | 13.35IN |
| Phase | 3 |
| Power Factor | 71 |
| Product Family | DirtyDutyPlus |
| Pull-Up Torque | 7.57LB-FT |
| Pulley End Bearing Type | SealedBearing |
| Pulley Face Code | C-Face |
| Pulley Shaft Indicator | Standard |
| Rodent Screen | None |
| RoHS Status | ROHSCOMPLIANT |
| RPM | 1700 - 1800 |
| Service Factor | 1.15 |
| Shaft Diameter | 0.875IN |
| Shaft Extension Location | PulleyEnd |
| Shaft Ground Indicator | NoShaftGrounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | NoSlinger |
| Speed | 1760rpm |
| Speed Code | SingleSpeed |
| Start Configuration | DOL |
| Starting Current | 14.6A |
| Starting Method | Directonline |
| Synchronous Speed @ Frequency | 1800RPM@60HZ |
| Temp. Rise @ Rated Load | 36°C |
| Temp. Rise @ S.F. Load | 41°C |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | NoVibrationSensor |
| Voltage | 230/460 |
| Voltage @ Frequency | 460.0V@60HZ |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Class and Group | None |
| XP Division | NotApplicable |