Agency ApprovalsCSAEEVAgency approvalsCSA EEVAmbient Temperature40°CAmbient temperature (°C)40Auxillary BoxNoAuxillaryBoxAuxillary boxNo auxillary boxAuxillary Box Lead TerminationNoneBase IndicatorRigidBase indicatorRigidBearing Grease TypePolyrexEM(-20F+300F)Bearing grease typePolyrex EM (-20F +300F)BlowerNoneBreak-Down Torque5.5LB-FTBreak-down torque5.5 lb-ftConduit Box MaterialSteelConstant Torque Speed Range6Constant torque speed range6Current @ Voltage1.700A@230.0VCurrent @ voltage1.700 A @ 230.0 VDesign CodeBDesign codeBDrip CoverNoDripCoverDrip coverNo drip coverDuty RatingCONTDuty ratingCONTEfficiency @ 100% Load80.0%Efficiency @ 100% load80.0 %Electrically Isolated BearingNotElectricallyIsolatedElectrically isolated bearingNot electrically isolatedEnclosureXPFCFeedback DeviceNOFEEDBACKFeedback deviceNo feedbackFrame56CFrame MaterialSteelFrame materialSteelFrequency50.00 HzFull Load Torque0LB-FTFull load torque0 lb-ftHeater IndicatorNoHeaterHeater indicatorNo heaterHigh Voltage Full Load Amps0.8aHigh voltage full load amps0.8 aHP1/3 HpInsulation ClassFInsulation classFInverter CodeInverterDutyInverter codeInverter dutyIP RatingNONEKVA CodeSKVA codeSLifting LugsNoLiftingLugsLifting lugsNo lifting lugsLine-line res @ 25° C43.2 Ohms A Ph / 0 Ohms B PhLine-Line Res. @ 25° C43.2OhmsAPh/0OhmsBPhLocked Bearing IndicatorLockedBearingLocked bearing indicatorLocked bearingLocked-Rotor Torque3.69LB-FTLocked-rotor torque3.69 lb-ftMax Speed2700 RPMMotor Lead TerminationFlyingLeadsMotor lead terminationFlying leadsMotor Letter TypeThreePhaseMotor letter typeThree phaseMotor StandardsNEMAMotor standardsNEMAMotor Type3512MMotor type3512MMotor Weight37Mounting ArrangementF1Mounting arrangementF1No-Load Current0ANo-load current0 ANumber of Poles4Number of poles4Output @ Frequency.250HP@50HZOutput @ frequency.250 HP @ 50 HZOverall Length14.30 inPhase3Power Factor49Power factor49Product FamilyGeneralPurposeProduct familyGeneral PurposePull-Up Torque2.98LB-FTPull-up torque2.98
| Agency Approvals | CSAEEV |
| Agency approvals | CSA EEV |
| Ambient Temperature | 40°C |
| Ambient temperature (°C) | 40 |
| Auxillary Box | NoAuxillaryBox |
| Auxillary box | No auxillary box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Base indicator | Rigid |
| Bearing Grease Type | PolyrexEM(-20F+300F) |
| Bearing grease type | Polyrex EM (-20F +300F) |
| Blower | None |
| Break-Down Torque | 5.5LB-FT |
| Break-down torque | 5.5 lb-ft |
| Conduit Box Material | Steel |
| Constant Torque Speed Range | 6 |
| Constant torque speed range | 6 |
| Current @ Voltage | 1.700A@230.0V |
| Current @ voltage | 1.700 A @ 230.0 V |
| Design Code | B |
| Design code | B |
| Drip Cover | NoDripCover |
| Drip cover | No drip cover |
| Duty Rating | CONT |
| Duty rating | CONT |
| Efficiency @ 100% Load | 80.0% |
| Efficiency @ 100% load | 80.0 % |
| Electrically Isolated Bearing | NotElectricallyIsolated |
| Electrically isolated bearing | Not electrically isolated |
| Enclosure | XPFC |
| Feedback Device | NOFEEDBACK |
| Feedback device | No feedback |
| Frame | 56C |
| Frame Material | Steel |
| Frame material | Steel |
| Frequency | 50.00 Hz |
| Full Load Torque | 0LB-FT |
| Full load torque | 0 lb-ft |
| Heater Indicator | NoHeater |
| Heater indicator | No heater |
| High Voltage Full Load Amps | 0.8a |
| High voltage full load amps | 0.8 a |
| HP | 1/3 Hp |
| Insulation Class | F |
| Insulation class | F |
| Inverter Code | InverterDuty |
| Inverter code | Inverter duty |
| IP Rating | NONE |
| KVA Code | S |
| KVA code | S |
| Lifting Lugs | NoLiftingLugs |
| Lifting lugs | No lifting lugs |
| Line-line res @ 25° C | 43.2 Ohms A Ph / 0 Ohms B Ph |
| Line-Line Res. @ 25° C | 43.2OhmsAPh/0OhmsBPh |
| Locked Bearing Indicator | LockedBearing |
| Locked bearing indicator | Locked bearing |
| Locked-Rotor Torque | 3.69LB-FT |
| Locked-rotor torque | 3.69 lb-ft |
| Max Speed | 2700 RPM |
| Motor Lead Termination | FlyingLeads |
| Motor lead termination | Flying leads |
| Motor Letter Type | ThreePhase |
| Motor letter type | Three phase |
| Motor Standards | NEMA |
| Motor standards | NEMA |
| Motor Type | 3512M |
| Motor type | 3512M |
| Motor Weight | 37 |
| Mounting Arrangement | F1 |
| Mounting arrangement | F1 |
| No-Load Current | 0A |
| No-load current | 0 A |
| Number of Poles | 4 |
| Number of poles | 4 |
| Output @ Frequency | .250HP@50HZ |
| Output @ frequency | .250 HP @ 50 HZ |
| Overall Length | 14.30 in |
| Phase | 3 |
| Power Factor | 49 |
| Power factor | 49 |
| Product Family | GeneralPurpose |
| Product family | General Purpose |
| Pull-Up Torque | 2.98LB-FT |
| Pull-up torque | 2.98 lb-ft |
| Pulley Face Code | C-Face |
| Pulley face code | C-face |
| Rodent Screen | None |
| Service Factor | 1.15 |
| Service factor | 1.15 |
| Shaft Diameter | 0.625 in |
| Shaft Ground Indicator | NoShaftGrounding |
| Shaft ground indicator | No shaft grounding |
| Shaft Rotation | Reversible |
| Shaft rotation | Reversible |
| Speed | 1780 rpm |
| Speed Code | SingleSpeed |
| Speed code | Single speed |
| Start Configuration | DOL |
| Start configuration | DOL |
| Starting Current | 6.08A |
| Starting current | 6.08 A |
| Starting Method | Directonline |
| Starting method | Direct on line |
| Synchronous RPM | 1800 |
| Synchronous Speed @ Frequency | 1800RPM@60HZ |
| Synchronous speed @ frequency | 1800 RPM @ 60 HZ |
| Temp rise @ rated load | 17° C |
| Temp rise @ SF load | 18° C |
| Temp. Rise @ Rated Load | 17°C |
| Temp. Rise @ S.F. Load | 18°C |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | NormallyClosedThermostat |
| Thermal device - winding | Normally closed thermostat |
| Vibration Sensor Indicator | NoVibrationSensor |
| Vibration sensor indicator | No vibration sensor |
| Voltage | 230/460 |
| Voltage @ Frequency | 380.0V@50HZ |
| Voltage @ frequency | 380.0 V @ 50 HZ |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Class and Group | CLIGPD;CLIIGPF, G |
| XP class and group | CLI GP D; CLII GP F,G |
| XP Division | DivisionI |
| XP division | Division I |
| XP Temp Code | T3C |
| XP temp code | T3C |