- New
Agency ApprovalsULAgency approvalsULAmbient Temperature40°CAmbient temperature (°C)40Auxillary BoxNoAuxillaryBoxAuxillary boxNo auxillary boxAuxillary Box Lead TerminationNoneBase IndicatorRigidBase indicatorRigidBearing Grease TypePolyrexEM(-20F+300F)Bearing grease typePolyrex EM (-20F +300F)BlowerNoneBreak-Down Torque18.6LB-FTBreak-down torque18.6 lb-ftConduit Box MaterialSteelConstant Torque Speed Range3Constant torque speed range3Current @ Voltage5.800A@208.0VCurrent @ voltage5.800 A @ 208.0 VDesign CodeBDesign codeBDrip CoverNoDripCoverDrip coverNo drip coverDuty RatingCONTDuty ratingCONTEfficiency @ 100% Load86.5%Efficiency @ 100% load86.5 %Electrically Isolated BearingNotElectricallyIsolatedElectrically isolated bearingNot electrically isolatedEnclosureXPFCFeedback DeviceNOFEEDBACKFeedback deviceNo feedbackFrame145TFrame MaterialSteelFrame materialSteelFrequency50.00 HzFront Shaft IndicatorNoneFull Load Torque0LB-FTFull load torque0 lb-ftHeater IndicatorNoHeaterHeater indicatorNo heaterHigh Voltage Full Load Amps2.6aHigh voltage full load amps2.6 aHP2 HpInsulation ClassFInsulation classFInverter CodeInverterReadyInverter codeInverter readyIP RatingNONEKVA CodeKKVA codeKLifting LugsNoLiftingLugsLifting lugsNo lifting lugsLine-line res @ 25° C9.54 Ohms A Ph / 0 Ohms B PhLine-Line Res. @ 25° C9.54OhmsAPh/0OhmsBPhLocked Bearing IndicatorNoLockedBearingLocked bearing indicatorNo locked bearingLocked-Rotor Torque14.4LB-FTLocked-rotor torque14.4 lb-ftMax Speed2700 RPMMotor Lead Quantity/Wire Size9@18AWGMotor lead quantity/wire size9 @ 18 AWGMotor Lead TerminationFlyingLeadsMotor lead terminationFlying leadsMotor Letter TypeThreePhaseMotor letter typeThree phaseMotor StandardsNEMAMotor standardsNEMAMotor TypeX3528MMotor typeX3528MMotor Weight59Mounting ArrangementF1Mounting arrangementF1No-Load Current0ANo-load current0 ANumber of Poles4Number of poles4Output @ Frequency2.000HP@60HZOutput @ frequency2.000 HP @ 60 HZOverall Length15.23 INPhase3Power Factor77Power fact
| Agency Approvals | UL |
| Agency approvals | UL |
| Ambient Temperature | 40°C |
| Ambient temperature (°C) | 40 |
| Auxillary Box | NoAuxillaryBox |
| Auxillary box | No auxillary box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Base indicator | Rigid |
| Bearing Grease Type | PolyrexEM(-20F+300F) |
| Bearing grease type | Polyrex EM (-20F +300F) |
| Blower | None |
| Break-Down Torque | 18.6LB-FT |
| Break-down torque | 18.6 lb-ft |
| Conduit Box Material | Steel |
| Constant Torque Speed Range | 3 |
| Constant torque speed range | 3 |
| Current @ Voltage | 5.800A@208.0V |
| Current @ voltage | 5.800 A @ 208.0 V |
| Design Code | B |
| Design code | B |
| Drip Cover | NoDripCover |
| Drip cover | No drip cover |
| Duty Rating | CONT |
| Duty rating | CONT |
| Efficiency @ 100% Load | 86.5% |
| Efficiency @ 100% load | 86.5 % |
| Electrically Isolated Bearing | NotElectricallyIsolated |
| Electrically isolated bearing | Not electrically isolated |
| Enclosure | XPFC |
| Feedback Device | NOFEEDBACK |
| Feedback device | No feedback |
| Frame | 145T |
| Frame Material | Steel |
| Frame material | Steel |
| Frequency | 50.00 Hz |
| Front Shaft Indicator | None |
| Full Load Torque | 0LB-FT |
| Full load torque | 0 lb-ft |
| Heater Indicator | NoHeater |
| Heater indicator | No heater |
| High Voltage Full Load Amps | 2.6a |
| High voltage full load amps | 2.6 a |
| HP | 2 Hp |
| Insulation Class | F |
| Insulation class | F |
| Inverter Code | InverterReady |
| Inverter code | Inverter ready |
| IP Rating | NONE |
| KVA Code | K |
| KVA code | K |
| Lifting Lugs | NoLiftingLugs |
| Lifting lugs | No lifting lugs |
| Line-line res @ 25° C | 9.54 Ohms A Ph / 0 Ohms B Ph |
| Line-Line Res. @ 25° C | 9.54OhmsAPh/0OhmsBPh |
| Locked Bearing Indicator | NoLockedBearing |
| Locked bearing indicator | No locked bearing |
| Locked-Rotor Torque | 14.4LB-FT |
| Locked-rotor torque | 14.4 lb-ft |
| Max Speed | 2700 RPM |
| Motor Lead Quantity/Wire Size | 9@18AWG |
| Motor lead quantity/wire size | 9 @ 18 AWG |
| Motor Lead Termination | FlyingLeads |
| Motor lead termination | Flying leads |
| Motor Letter Type | ThreePhase |
| Motor letter type | Three phase |
| Motor Standards | NEMA |
| Motor standards | NEMA |
| Motor Type | X3528M |
| Motor type | X3528M |
| Motor Weight | 59 |
| Mounting Arrangement | F1 |
| Mounting arrangement | F1 |
| No-Load Current | 0A |
| No-load current | 0 A |
| Number of Poles | 4 |
| Number of poles | 4 |
| Output @ Frequency | 2.000HP@60HZ |
| Output @ frequency | 2.000 HP @ 60 HZ |
| Overall Length | 15.23 IN |
| Phase | 3 |
| Power Factor | 77 |
| Power factor | 77 |
| Product Family | GeneralPurpose |
| Product family | General Purpose |
| Pull-Up Torque | 13.3LB-FT |
| Pull-up torque | 13.3 lb-ft |
| Pulley End Bearing Type | Ball |
| Pulley end bearing type | Ball |
| Pulley Face Code | Standard |
| Pulley face code | Standard |
| Pulley Shaft Indicator | Standard |
| Pulley shaft indicator | Standard |
| Rodent Screen | None |
| RoHS Status | ROHSNON-COMPLIANT |
| RoHS status | ROHS NON-COMPLIANT |
| Service Factor | 1 |
| Service factor | 1.00 |
| Shaft Diameter | 0.875 in |
| Shaft Ground Indicator | NoShaftGrounding |
| Shaft ground indicator | No shaft grounding |
| Shaft Rotation | Reversible |
| Shaft rotation | Reversible |
| Shaft Slinger Indicator | NoSlinger |
| Shaft slinger indicator | No slinger |
| Speed | 1465 rpm |
| Speed Code | SingleSpeed |
| Speed code | Single speed |
| Start Configuration | DOL |
| Start configuration | DOL |
| Starting Current | 21A |
| Starting current | 21 A |
| Starting Method | Directonline |
| Starting method | Direct on line |
| Synchronous RPM | 1800 |
| Synchronous Speed @ Frequency | 1800RPM@60HZ |
| Synchronous speed @ frequency | 1800 RPM @ 60 HZ |
| Temp rise @ rated load | 58° C |
| Temp. Rise @ Rated Load | 58°C |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | NormallyClosedThermostat |
| Thermal device - winding | Normally closed thermostat |
| Vibration Sensor Indicator | NoVibrationSensor |
| Vibration sensor indicator | No vibration sensor |
| Voltage | 230/460 |
| Voltage @ Frequency | 190.0V@50HZ |
| Voltage @ frequency | 190.0 V @ 50 HZ |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Class and Group | CLIGPD;CLIIGPF, G |
| XP class and group | CLI GP D; CLII GP F,G |
| XP Division | DivisionI |
| XP division | Division I |
| XP Temp Code | T3C |
| XP temp code | T3C |