Agency ApprovalsCSAEEVAmbient Temperature40°CAuxillary BoxNoAuxillaryBoxAuxillary Box Lead TerminationNoneBase IndicatorRigidBearing Grease TypePolyrexEM(-20F+300F)BlowerNoneBreak-Down Torque56.3LB-FTConduit Box MaterialCast IronCurrent @ Voltage24.800A@208.0VDesign CodeBDrip CoverNoDripCoverDuty RatingCONTEfficiency @ 100% Load90.2%Electrically Isolated BearingNotElectricallyIsolatedEnclosureTEFCFeedback DeviceNOFEEDBACKFrame215TFrame MaterialIronFrequency60.00HzFull Load Torque0LB-FTHeater IndicatorNoHeaterHigh Voltage Full Load Amps11.8aHP10Hz60Insulation ClassHInverter CodeInverterReadyIP RatingNONEKVA CodeGLifting LugsStandardLiftingLugsLine-Line Res. @ 25° C1.05OhmsAPh/0OhmsBPhLocked Bearing IndicatorLockedBearingLocked-Rotor Torque23.8LB-FTMotor Lead TerminationFlyingLeadsMotor Letter TypeThreePhaseMotor StandardsNEMAMotor Type0730MMotor Weight164Mounting ArrangementF1No-Load Current0ANumber of Poles2Output @ Frequency10.000HP@60HZOverall Length18.45INPhase3Power Factor87Product FamilyGeneralPurposePull-Up Torque17.7LB-FTPulley Face CodeStandardRodent ScreenNoneRPM3400 - 3600Service Factor1.15Shaft Diameter1.375INShaft Ground IndicatorShaftGroundingShaft RotationReversibleSpeed3490rpmSpeed CodeSingleSpeedStart ConfigurationDOLStarting Current78.5AStarting MethodDirectonlineSynchronous RPM3600Synchronous Speed @ Frequency3600RPM@60HZTemp. Rise @ Rated Load63°CTemp. Rise @ S.F. Load79°CThermal Device - BearingNoneThermal Device - WindingNoneVibration Sensor IndicatorNoVibrationSensorVoltage230/460Voltage @ Frequency460.0V@60HZWinding Thermal 1NoneWinding Thermal 2NoneXP Class and GroupNoneXP DivisionNotApplicable
| Agency Approvals | CSAEEV |
| Ambient Temperature | 40°C |
| Auxillary Box | NoAuxillaryBox |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | PolyrexEM(-20F+300F) |
| Blower | None |
| Break-Down Torque | 56.3LB-FT |
| Conduit Box Material | Cast Iron |
| Current @ Voltage | 24.800A@208.0V |
| Design Code | B |
| Drip Cover | NoDripCover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 90.2% |
| Electrically Isolated Bearing | NotElectricallyIsolated |
| Enclosure | TEFC |
| Feedback Device | NOFEEDBACK |
| Frame | 215T |
| Frame Material | Iron |
| Frequency | 60.00Hz |
| Full Load Torque | 0LB-FT |
| Heater Indicator | NoHeater |
| High Voltage Full Load Amps | 11.8a |
| HP | 10 |
| Hz | 60 |
| Insulation Class | H |
| Inverter Code | InverterReady |
| IP Rating | NONE |
| KVA Code | G |
| Lifting Lugs | StandardLiftingLugs |
| Line-Line Res. @ 25° C | 1.05OhmsAPh/0OhmsBPh |
| Locked Bearing Indicator | LockedBearing |
| Locked-Rotor Torque | 23.8LB-FT |
| Motor Lead Termination | FlyingLeads |
| Motor Letter Type | ThreePhase |
| Motor Standards | NEMA |
| Motor Type | 0730M |
| Motor Weight | 164 |
| Mounting Arrangement | F1 |
| No-Load Current | 0A |
| Number of Poles | 2 |
| Output @ Frequency | 10.000HP@60HZ |
| Overall Length | 18.45IN |
| Phase | 3 |
| Power Factor | 87 |
| Product Family | GeneralPurpose |
| Pull-Up Torque | 17.7LB-FT |
| Pulley Face Code | Standard |
| Rodent Screen | None |
| RPM | 3400 - 3600 |
| Service Factor | 1.15 |
| Shaft Diameter | 1.375IN |
| Shaft Ground Indicator | ShaftGrounding |
| Shaft Rotation | Reversible |
| Speed | 3490rpm |
| Speed Code | SingleSpeed |
| Start Configuration | DOL |
| Starting Current | 78.5A |
| Starting Method | Directonline |
| Synchronous RPM | 3600 |
| Synchronous Speed @ Frequency | 3600RPM@60HZ |
| Temp. Rise @ Rated Load | 63°C |
| Temp. Rise @ S.F. Load | 79°C |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | NoVibrationSensor |
| Voltage | 230/460 |
| Voltage @ Frequency | 460.0V@60HZ |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Class and Group | None |
| XP Division | NotApplicable |