- New
Adjustable rated motor currentNoBy-pass signal relayYesCommunicationFiledBusPlug(Optional)Connecting capacity control circuit1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1/2 x 0.75 ... 2.5 mm²Connecting capacity main circuitRigid 1/2 x 0.75 ... 2.5 mm²Connecting capacity supply circuitRigid 1 x 0.75 ... 2.5 mm²Current limit functionNoDegree of protectionIP20Fault signal relayNoFunctionSingle directionInitial voltage during start40 ... 70 %Integrated electronic overloadNoNumber of starts per hour at 3.5*Ie for 7 sec. 50% ON time 50% OFF time10Overload protectionRecommended MS132 25 ... 32Overload signal relayNoProduct main typePSR30Ramp time0 ... 20 second [unit of time]1 ... 10 second [unit of time]Rated control circuit voltage24 V DCRated control supply voltage24 V AC/DCRated operational current - in-line connection30 ARated operational power - in-line connection(230 V) 7.5 kW(400 V) 15 kW(500 V) 18.5 kWRated operational voltage208 ... 600 V ACRun signal relayYesService factor percentage100.00%Signal indication completed start rampGreenSignal indication ramping up/downGreenSignal indication ready to start/standby ONGreenSignal indication running RGreenStarting capacity at maximum rated current4xIe for 6sStep down voltage special ramp100 ... 60 %Switch for inside delta connectionNoTightening torqueControl Circuit 0.6 N·mMain Circuit 2.3 N·mSupply Circuit 0.6 N·m
| Adjustable rated motor current | No |
| By-pass signal relay | Yes |
| Communication | FiledBusPlug(Optional) |
| Connecting capacity control circuit | 1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1/2 x 0.75 ... 2.5 mm² |
| Connecting capacity main circuit | Rigid 1/2 x 0.75 ... 2.5 mm² |
| Connecting capacity supply circuit | Rigid 1 x 0.75 ... 2.5 mm² |
| Current limit function | No |
| Degree of protection | IP20 |
| Fault signal relay | No |
| Function | Single direction |
| Initial voltage during start | 40 ... 70 % |
| Integrated electronic overload | No |
| Number of starts per hour at 3.5*Ie for 7 sec. 50% ON time 50% OFF time | 10 |
| Overload protection | Recommended MS132 25 ... 32 |
| Overload signal relay | No |
| Product main type | PSR30 |
| Ramp time | 0 ... 20 second [unit of time]1 ... 10 second [unit of time] |
| Rated control circuit voltage | 24 V DC |
| Rated control supply voltage | 24 V AC/DC |
| Rated operational current - in-line connection | 30 A |
| Rated operational power - in-line connection | (230 V) 7.5 kW(400 V) 15 kW(500 V) 18.5 kW |
| Rated operational voltage | 208 ... 600 V AC |
| Run signal relay | Yes |
| Service factor percentage | 100.00% |
| Signal indication completed start ramp | Green |
| Signal indication ramping up/down | Green |
| Signal indication ready to start/standby ON | Green |
| Signal indication running R | Green |
| Starting capacity at maximum rated current | 4xIe for 6s |
| Step down voltage special ramp | 100 ... 60 % |
| Switch for inside delta connection | No |
| Tightening torque | Control Circuit 0.6 N·mMain Circuit 2.3 N·mSupply Circuit 0.6 N·m |